CHILLER CLIMMA DC35 35000 BTU
Power Supply: 230V - 50-60 Hz
Capacity (Cool Mode): 2.5 - 10 kW (8k - 35k Btu)
Capacity (Heat Mode): 2.5 - 10 kW (8k - 35k Btu)
Power Consuption (A) - Cool Mode: 0 A - 9.5 A
Power Consumption (kW) - Cool Mode: 0 kW - 2.2 kW
Refrigerant and Charge: R410a
Fresh Water Flow (m3/h): 1.8
Sea Water Flow (m3/h): 1.8
Sea Water Temp. (Heat Mode): > 5 °C
Sea Water Temp. (Cool Mode): < 38 °C
Size (LxDxH in mm): 335 x 342 x 472
electricl Box (LxDxH in mm): 240 x 190 x 90
Weight: 48 Kg.
- Phase
- Single phase
- Frequency (Hz)
- 50 / 60
- Voltage (V)
- 230
- Cooling
- Water
- Maximum flow (m³/h)
- 1.8
- Inlet diameter thread type (mm/inches)
- 16 mm Fresh Water / 25mm Sea Water
- Outlet diameter thread type (mm/inches)
- 16 mm Fresh Water / 25mm Sea Water
- Maximum permissible current (A)
- 13 A
- Refrigerating yield
- 35000 BTU / 10 KW
- Heating power
- 35000 BTU / 10 KW
- Length (mm)
- 335
- Width (mm)
- 342
- Height (mm)
- 472
- Dry weight (Kg)
- 48
- Type of climate control
- Chiller
- Power consumption (W)
- 2200
- Voltage regulator
- Inverter
- Coolant
- R410A
CHILLER CLIMMA DC35 35000 BTU
CWS INVERTER DC 35 RC 230/1/50-60
The new Climma DC35 chiller is the latest new entry in the Climma DC serie of variable speed chillers; running from 5,000 up to 35,000 Btu. The smallest size on the market thanks to the unique water cooled inverter.
• Variable Output
Climma’s new DC chiller is programmed to run at the optimum speed; depending on the heat load requirements, the compressor frequency varies controlling the output capacity from 5,000 to 35,000 Btu.
• Unique Water Cooled Inverter
Unique in the marine industry, Climma’s water cooled inverter protects the compressor from excessive temperature and irregular voltage supply, allowing it to be installed in the engine room without additional ventilation.
• Climma Intelligent Control
Heating and cooling capacity is managed by the Climma Intelligent Control unit (CIC) which uses specially congured
algorithms to ensure maximum eciency.
• ECO mode
Climma DC chillers provide further eciency gain through a special ECO mode. ECO mode enables the chiller to work when only a courtesy/night generator is working or even while on the dock with a limited shore power supply.
• No Start Load
Climma DC chiller requires no additional amps to start the compressor.
• Modularity
Each Climma DC chiller can be installed independently, or with a modular conguration up to 4 units, for system up to 140,000 Btu, achieving variable output with full redundancy.
CLIMMA REMOTE MECHANICAL PANEL FOR CWS DC INVERTER
CLIMMA CIRCULATION PUMP NMM2/S/A
OBLIQUE FILTER 1" FF BRONZE
CLIMMA EXPANSION TANK 8 LITRES
CLIMMA AUTOMATIC AIR BLEEDER 1''
CLIMMA VALVE CALIBRATION 1" BZ 2260
- Phase
- Single phase
- Frequency (Hz)
- 50 / 60
- Voltage (V)
- 230
- Cooling
- Water
- Maximum flow (m³/h)
- 1.8
- Inlet diameter thread type (mm/inches)
- 16 mm Fresh Water / 25mm Sea Water
- Outlet diameter thread type (mm/inches)
- 16 mm Fresh Water / 25mm Sea Water
- Maximum permissible current (A)
- 13 A
- Refrigerating yield
- 35000 BTU / 10 KW
- Heating power
- 35000 BTU / 10 KW
- Length (mm)
- 335
- Width (mm)
- 342
- Height (mm)
- 472
- Dry weight (Kg)
- 48
- Type of climate control
- Chiller
- Power consumption (W)
- 2200
- Voltage regulator
- Inverter
- Coolant
- R410A