MECC ALTE ECP3-1L/4 THREE PHASE ALTERNATOR 11 KVA AVR
Phase: Single phase / Three phase
Maximum three phase power: 9.4 KW
Continuous three phase power: 8.8 KW
Maximum three phase power: 11.8 KVA
Continuous three phase power: 11 KVA
Maximum single phase power: 8 KW
Continuous single phase power: 7.5 KW
Maximum single phase power: 8 KVA
Continuous single phase power: 7.5 KVA
Frequency: 50 Hz
Voltage: 230 V / 400 V
Protection: IP23
Rpm speed: 1500 rpm
Poles: 4
Efficiency: 85.9%
Weight: 79 Kg
Constant speed alternator
Brushless
Voltage regulator: AVR
- Phase
- Single phase / Three phase
- Maximum power single phase (KW)
- 8.5
- Continuous power single phase (KW)
- 8
- Maximum power single phase (KVA)
- 8.5
- Continuous power single phase (KVA)
- 8
- Maximum power three phase (KW)
- 9.4
- Continuous power three phase (KW)
- 8.8
- Maximum power three phase (KVA)
- 11.8
- Continuous power three phase (KVA)
- 11
- Frequency (Hz)
- 50 / 60
- Voltage (V)
- 230 / 400
- Engine rpm (rpm)
- 1500 / 1800
- Poles
- 4
- Single-phase power (KVA)
- 7.5
- Three-phase power (KVA)
- 11.8
- Efficiency (%)
- 85.9
- Protection degree
- IP23
- Acoustic pressure
- 58 dB(A) at 7 m
- Brushes
- No
- PMG
- No
- Type of alternator
- Constant Speed
- Voltage regulator
- AVR
- Weight (Kg)
- 79
The ECP3 range has many product features designed into the alternator.
Self-regulation is obtained through a digital electronic regulator that is fed by an auxiliary winding.
We guarantee an almost constant supply from the generator - under any possible operating condition.
The versatility of Mecc Alte products and their robust design means that ECO and ECP series are formed to meet the requirements of industry and the high technological specifications of applications. They are available either as single bearing or as twin bearing with a double support. In order to couple them to a prime mover, it is possible to choose among a wide range of flanges and couplings.
All alternators consist of a fixed stator with skewed slots and a rotating inductor fitted. In addition, models above 15 KVA are fitted with a damper cage as standard. All alternator windings have a 2/3rd pitch in order to reduce harmonic content.
The generators manufactured by Mecc Alte are in compliance with the CEI 2-3 file 11111 national standard. This Italian standard corresponds to the European standard EN 60034-1 and to the international standard IEC 60034-1; it is related also to the British standard BS 4999 Part 101; it is equivalent to the German standard VDE 0530 Part 1, and it is included in the French standard NF 51.111. Mecc Alte generators meet also the requirements of international ISO 8528-3 standard (Reciprocating internal combustion engine driven alternating current generating sets – Part 3: Alternating current generators for generating sets) and the requirements of NEMA MG 1-2011 (Motors and Generators).
Not binding images and technical data.
MECC ALTE PARALLEL CURRENT TRANSFORMER TA (INCLUDING SADDLE WHEN REQUIRED) FOR ECP3 ALTERNATORS
MECC ALTE PARALLEL CURRENT TRANSFORMER TA (INCLUDING SADDLE WHEN REQUIRED) FOR ECP3 ALTERNATORS
MECC ALTE VOLTAGE CONTROL POTENTIOMETER FOR ECP3 ALTERNATORS
MECC ALTE DIODE RBD-1 FAILURE SENSOR FOR ECP3 ALTERNATORS
MECC ALTE COUPLING BELL FOR TYPE B3-B14 FOR ECP3 ALTERNATORS
MECC ALTE PTCK150 TEMPERATURE SENSOR (1 SET OF 3) FOR ECP3 ALTERNATORS
MECC ALTE PT100 RTD SENSOR ON WINDINGS (1 OF 3) FOR ECP3 ALTERNATORS
MECC ALTE PT100 RTD SENSOR ON WINDINGS (2 OF 3) FOR ECP3 ALTERNATORS
MECC ALTE PT100 RTD (FOR BEARING) FOR ECP3 ALTERNATORS
MECC ALTE BIMETALLIC PROBE (THERMAL PROTECTION) FOR ECP3 ALTERNATORS
MECC ALTE DER1 AVR (THREE PHASE SENSING) (+/- 0.5%) (FACTORY FITTED ONLY) FOR ECP3 ALTERNATORS
MECC ALTE DER1 AVR (THREE PHASE SENSING) (+/- 0.5%) (FACTORY FITTED ONLY) FOR ECP3 ALTERNATORS
MECC ALTE USB 2 DxR DIGITAL INTERFACE FOR ECP3 ALTERNATORS
MECC ALTE DER2 AVR (THREE PHASE SENSING INTEGRATED USB) (+/- 0.5%) (FACTORY FITTED ONLY) FOR ECP3 ALTERNATORS
MECC ALTE AIR FILTER FOR REAR INLET (LOSS 7%) FOR ECP3 ALTERNATORS
MECC ALTE IP45 PROTECTION SCREEN (DERATING APPLIES) FOR ECP3 ALTERNATORS
MECC ALTE ANTI-CONDENSATION HEATER - REAR PART (FACTORY FITTED) FOR ECP3 ALTERNATORS
MECC ALTE ANTI-CONDENSATION HEATER - FRONT PART (FACTORY FITTED) FOR ECP3 ALTERNATORS
MECC ALTE ANTI-CONDENSATION HEATER ON THE REAR SHIELD (CAN BE INTEGRATED) FOR ECP3 ALTERNATORS
MECC ALTE ANTI-CONDENSATION HEATER ON THE REAR SHIELD (CAN BE INTEGRATED) FOR ECP3 ALTERNATORS
MECC ALTE STANDARD IMPREGNATION + (GREY STATOR EXCITER) FOR ECP3 ALTERNATORS
MECC ALTE GREY IMPREGNATION (EXCITER AND MAIN STATOR GREY) FOR ECP3 ALTERNATORS
MECC ALTE GREY IMPREGNATION + (GREY MAIN STATOR AND BLACK EXCITER STATOR) FOR ECP3 ALTERNATORS
MECC ALTE GREY IMPREGNATION + (GREY MAIN STATOR AND BLACK EXCITER STATOR) FOR ECP3 ALTERNATORS
MECC ALTE TOTAL IMPREGNATION + (BLACK MAIN STATOR & EXCITER STATOR, GREY ROTOR) FOR ECP3 ALTERNATORS
MECC ALTE TOTAL IMPREGNATION + (BLACK MAIN STATOR & EXCITER STATOR, GREY ROTOR) FOR ECP3 ALTERNATORS
- Phase
- Single phase / Three phase
- Maximum power single phase (KW)
- 8.5
- Continuous power single phase (KW)
- 8
- Maximum power single phase (KVA)
- 8.5
- Continuous power single phase (KVA)
- 8
- Maximum power three phase (KW)
- 9.4
- Continuous power three phase (KW)
- 8.8
- Maximum power three phase (KVA)
- 11.8
- Continuous power three phase (KVA)
- 11
- Frequency (Hz)
- 50 / 60
- Voltage (V)
- 230 / 400
- Engine rpm (rpm)
- 1500 / 1800
- Poles
- 4
- Single-phase power (KVA)
- 7.5
- Three-phase power (KVA)
- 11.8
- Efficiency (%)
- 85.9
- Protection degree
- IP23
- Acoustic pressure
- 58 dB(A) at 7 m
- Brushes
- No
- PMG
- No
- Type of alternator
- Constant Speed
- Voltage regulator
- AVR
- Weight (Kg)
- 79