CGM 1360P - OPEN WITH AUTOMATIC CONTROL UNIT

CGM 25NG GAS METANO - APERTO CON CENTRALINA MANUALE
search
  • CGM 25NG GAS METANO - APERTO CON CENTRALINA MANUALE
  • CGM 25NG GAS METANO - APERTO CON CENTRALINA MANUALE
CGM
CGM 1360P APERTO AUTOMATICO
New product

Maximum three-phase power: 1197 KW
Three-phase continuous power: 1088 KW
Maximum three-phase power: 1496 KVA
Three-phase continuous use power: 1360 KVA
Fuel: Diesel
Voltage: 400 V + N
Frequency: 50 Hz
Current A: 1963 A
Power factor cos: 0.8
Electrical protection: IP44
Motor: PERKINS 4012 46TWG3A
Displacement cc: 45842
Engine speed: 1500 rpm
Bore x stroke: 160 x 190 mm
Suction: Turbo
Speed governor: Electronic
Number and arrangement of cylinders: V12 60°
Cooling system: Water
Starter: Electric
Alternator: MARELLI MOTORS, brushless
Poles: 4
Voltage regulator system: AVR
Consumption: 213 Lt/h at 75% load / 283 Lt/h at 100% load
Tank capacity: 400 Lt
Autonomy: 1.9 h at 75% load
Length: 4900 mm
Width: 2100 mm
Height: 2400 mm
Weight: 9800 K

Technical features
Phase
Single phase / Three phase
Maximum power three phase (KW)
1197
Continuous power three phase (KW)
1088
Maximum power three phase (KVA)
1496
Continuous power three phase (KVA)
1360
Fuel
Diesel
Frequency (Hz)
50
Voltage (V)
230 / 400
Engine
PERKINS 403A-11G
Engine rpm (rpm)
1500
Speed governor
Electronic
Starting system
Electric
Engine capacity (cm³)
45842
Number cylinders
12
Cylinders' position
V 60°
Cooling
Water
Alternator
Marelli, brushless
Poles
4
Protection degree
IP44
Bore x stroke (mm)
160 x 190
Fuel tank capacity (L)
400
Consumption (L/h)
213
Running time (h)
1.9
Length (mm)
4900
Width (mm)
2100
Height (mm)
2400
Dry weight (Kg)
9800
Silenced
No
Super silenced
No
ATS Switch device
Optional
Voltage regulator
AVR
Engine manufacturer
Perkins
Details

CGM 1360P - OPEN WITH AUTOMATIC CONTROL UNIT

The CGM 1360P - OPEN WITH AUTOMATIC CONTROLLER is a petrol-driven, open genset with automatic control unit. It is a versatile model, suitable for a variety of applications, including:

CGM 1360P Emergency supply: In the event of a blackout, the CGM genset 1360P can supply to homes, offices and other buildings.

Professional applications: The CGM 1360P is ideal for professional applications that require a reliable power source, such as construction sites, industry and business.

The CGM 1360P is equipped with a PERKINS 4012 46TWG3A petrol engine. The engine is water-cooled to ensure high reliability and durability.

Technical specifications CGM 1360P:

Maximum three-phase power: 1197 KW
Three-phase continuous power: 1088 KW
Maximum three-phase power: 1496 KVA
Three-phase continuous use power: 1360 KVA
Fuel: Diesel
Voltage: 400 V + N
Frequency: 50 Hz
Current A: 1963 A
Power factor cos: 0.8
Electrical protection: IP44
Motor: PERKINS 4012 46TWG3A
Displacement cc: 45842
Engine speed: 1500 rpm
Bore x stroke: 160 x 190 mm
Suction: Turbo
Speed governor: Electronic
Number and arrangement of cylinders: V12 60°
Cooling system: Water
Starter: Electric
Alternator: MARELLI MOTORS, brushless
Poles: 4
Voltage regulator system: AVR
Consumption: 213 Lt/h at 75% load / 283 Lt/h at 100% load
Tank capacity: 400 Lt
Autonomy: 1.9 h at 75% load
Length: 4900 mm
Width: 2100 mm
Height: 2400 mm
Weight: 9800 Kg

The generator of the CGM 1360P - OPEN WITH AUTOMATIC CONTROL BOX is a 4-pole synchronous generator.

The automatic control unit of the CGM 1360P - OPEN WITH AUTOMATIC CONTROLLER. The control unit is equipped with a voltage sensor, which detects changes in the mains voltage and starts the genset in the event of a power failure.

The CGM 1360P - OPEN WITH AUTOMATIC CONTROL BOX is equipped with a series of safety devices, which guarantee its correct operation and the protection of the operator.

Advantages

Automatic control unit: The automatic control unit allows the genset to start and stop automatically, based on variations in mains voltage.

This is a significant advantage for emergency applications, as it ensures that the genset is always ready to supply power in the event of a blackout.

It allows a variety of devices and equipment to be powered, including household appliances, camping equipment and other devices for commercial use.

If you are looking for a product similar to or with similar features click HERE.

images purely indicative.

Technical Sheet / Manuals
Related Accessories
List price
484.071,60 € tax incl.
396.780,00 € tax excl.
Discounted Price
302.545,36 € tax incl.
247.988,00 € tax excl.
Quantity

loader
shipped to

Calculate Shipping Cost
Add to wishlist
Download PDF
Ask a question
Product: CGM 25NG GAS METANO - APERTO CON CENTRALINA MANUALE
Offer on letterhead
Product: CGM 25NG GAS METANO - APERTO CON CENTRALINA MANUALE
Technical features
Phase
Single phase / Three phase
Maximum power three phase (KW)
1197
Continuous power three phase (KW)
1088
Maximum power three phase (KVA)
1496
Continuous power three phase (KVA)
1360
Fuel
Diesel
Frequency (Hz)
50
Voltage (V)
230 / 400
Engine
PERKINS 403A-11G
Engine rpm (rpm)
1500
Speed governor
Electronic
Starting system
Electric
Engine capacity (cm³)
45842
Number cylinders
12
Cylinders' position
V 60°
Cooling
Water
Alternator
Marelli, brushless
Poles
4
Protection degree
IP44
Bore x stroke (mm)
160 x 190
Fuel tank capacity (L)
400
Consumption (L/h)
213
Running time (h)
1.9
Length (mm)
4900
Width (mm)
2100
Height (mm)
2400
Dry weight (Kg)
9800
Silenced
No
Super silenced
No
ATS Switch device
Optional
Voltage regulator
AVR
Engine manufacturer
Perkins
Details
Technical Sheet / Manuals