Type of phase: Single-phase / Three-phase
Maximum single-phase power: 4 KVA / 3.2 KW
Continuous single-phase power: 3.6 KVA / 3 KW
Maximum three-phase power: 12.1 KVA / 9.7 KW
Continuous three-phase power: 11 KVA / 8.8 KW
Fuel: Diesel
Voltage: 230/400 V
Frequency: 50 Hz
Power factor cos: 0.8
Socket configuration: 1 CEE 16A 3P 230V socket and 1 CEE 16A 5P 400V socket
Switch, thermal protection, voltmeter, hour counter
Motor: KOHLER KD425
Emissions Regulations : STAGE V
Displacement cc: 851
Engine revolutions: 3000 rpm
Number and arrangement of cylinders: 2
Cooling system: Air
Starting: Electric
Alternator: Linz or NSM
Poles: 2
Voltage regulator system: AVR
Consumption: 2.8 Lt / h at 75% of the load
Tank capacity: 4 Lt
Autonomy: 1.4 h at 75% of the load
Length: 910 mm
Width: 580 mm
Height: 640 mm
Weight: 170 Kg
- Phase
- Single phase / Three phase
- Maximum power single phase (KW)
- 3.2
- Continuous power single phase (KW)
- 3
- Maximum power single phase (KVA)
- 4
- Continuous power single phase (KVA)
- 3.6
- Maximum power three phase (KW)
- 9.7
- Continuous power three phase (KW)
- 8.8
- Maximum power three phase (KVA)
- 12
- Continuous power three phase (KVA)
- 11
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Sockets configuration
- 1 CEE 16A 3P 230V + 1 CEE 16A 5P 400V
- Engine
- Kohler KD 425/2
- Emissions Regulations
- Stage 5
- Engine rpm (rpm)
- 3000
- Starting system
- Electric
- Engine capacity (cm³)
- 851
- Number cylinders
- 2
- Cooling
- Air
- Alternator
- Linz or NSM
- Poles
- 2
- Fuel tank capacity (L)
- 4
- Consumption (L/h)
- 2.8 at 75% of the load
- Running time (h)
- 1.4 at 75% of the load
- Length (mm)
- 910
- Width (mm)
- 580
- Height (mm)
- 640
- Dry weight (Kg)
- 170
- Voltage regulator
- AVR
CGM D11000T THREE-PHASE GENERATOR 11KVA
Generator CGM D11000T with KOHLER KD425 STAGE V Diesel engine, capable of delivering a power of 11KVA, compact and easy to use, mounted on a fixed base with rubber vibration dampers.
The CGM D11000T Generator consists of a Made in Italy alternator from Linz or NSM, self-excited without brushes and with AVR voltage regulator. The CGM D11000T generator is equipped with electric start with 12V battery and with a low fuel consumption, in fact it consumes only 2,8 liters/hour at 75% of the load.
This generator is perfect for outdoor use such as hobby use. Also available with a panel for automatic starting with ATS.
The CGM D11000T generator is part of the CLASSIC DIESEL series and are characterized by lower consumption and a longer life expectancy than the gasoline-powered range. The 3000 rpm generator is suitable for emergency use only. It is not recommended to use it for more than 6 hours continuously and for more than 500 hours per year.
Technical Features of the CGM D11000T Generator
Type of phase: Singlephase / Threephase
Maximum singlephase power: 4 KVA / 3.2 KW
Continuous singlephase power: 3.6 KVA / 3 KW
Maximum threephase power: 12.1 KVA / 9.7 KW
Continuous threephase power: 11 KVA / 8.8 KW
Fuel: Diesel
Voltage: 230/400 V
Frequency: 50 Hz
Power factor cos: 0.8
Socket configuration: 1 CEE 16A 3P 230V socket and 1 CEE 16A 5P 400V socket
Switch, thermal protection, voltmeter, hour counter
Motor: KOHLER KD425
Emissions Regulations : STAGE V
Displacement cc: 851
Engine revolutions: 3000 rpm
Number and arrangement of cylinders: 2
Cooling system: Air
Starting: Electric
Alternator: Linz or NSM
Poles: 2
Voltage regulator system: AVR
Consumption: 2.8 Lt / h at 75% of the load
Tank capacity: 4 Lt
Autonomy: 1.4 h at 75% of the load
Length: 910 mm
Width: 580 mm
Height: 640 mm
Weight: 170 Kg
Are you looking for a generator with different technical characteristics? Here you can find the full range of CGM generators or other specialized brands.
The pictures and technical data are not binding and may be subject to revisions by the manufacturer.
CGM TROLLEY KIT FOR D1 SERIES
CGM AUTOMATIC SWITCHBOARD WITH ATS FOR D SERIES
CGM TANK INCREASED BY 15 LITRES FOR D SERIES
CGM TANK INCREASED BY 25 LITRES FOR D SERIES
- Phase
- Single phase / Three phase
- Maximum power single phase (KW)
- 3.2
- Continuous power single phase (KW)
- 3
- Maximum power single phase (KVA)
- 4
- Continuous power single phase (KVA)
- 3.6
- Maximum power three phase (KW)
- 9.7
- Continuous power three phase (KW)
- 8.8
- Maximum power three phase (KVA)
- 12
- Continuous power three phase (KVA)
- 11
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Sockets configuration
- 1 CEE 16A 3P 230V + 1 CEE 16A 5P 400V
- Engine
- Kohler KD 425/2
- Emissions Regulations
- Stage 5
- Engine rpm (rpm)
- 3000
- Starting system
- Electric
- Engine capacity (cm³)
- 851
- Number cylinders
- 2
- Cooling
- Air
- Alternator
- Linz or NSM
- Poles
- 2
- Fuel tank capacity (L)
- 4
- Consumption (L/h)
- 2.8 at 75% of the load
- Running time (h)
- 1.4 at 75% of the load
- Length (mm)
- 910
- Width (mm)
- 580
- Height (mm)
- 640
- Dry weight (Kg)
- 170
- Voltage regulator
- AVR