CUMMINS C300 D5 THREE-PHASED DIESEL POWER GENERATOR 275KVA SILENCED
Phase Type: Three-phase
Maximum power three-phase LTP: 300 KVA
Maximum power three-phase LTP: 240 KW
Continuous power three-phase PRP: 275 KVA
Maximum power three-phase LTP: 220 KVA
Fuel: Diesel
Frequency: 50 Hz
Voltage: 400 V
Engine: Cummins
Engine rpm: 1500 rpm
Cooling: Air
Length: 4259 mm
Width: 1424 mm
Height: 2349 mm
Dry Weight: 4348 Kg
Silenced
- Phase
- Three phase
- Maximum power three phase (KW)
- 240
- Continuous power three phase (KW)
- 220
- Maximum power three phase (KVA)
- 300
- Continuous power three phase (KVA)
- 275
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 400
- Sockets configuration
- Terminal box
- Engine
- 4 stroke
- Emissions Regulations
- Stationary Use
- Engine rpm (rpm)
- 1500
- Speed governor
- Mechanical
- Number cylinders
- 6
- Cylinders' position
- In line
- Cooling
- Air
- Poles
- 4
- Bore x stroke (mm)
- 91.4x127
- Length (mm)
- 4250
- Width (mm)
- 1438
- Height (mm)
- 2348
- Dry weight (Kg)
- 4300
- Silenced
- Yes
- Brushes
- No
- Product type
- Generator
- Control unit
- PowerStart 600
- ATS Switch device
- Optional
- Type of alternator
- Constant Speed
- Engine manufacturer
- Cummins
- Precision of voltage regulation
- ± 2,5%
CUMMINS C300 D5 Control system
Generator set control PowerStart 600
The PowerStart contol is a microprocessor-based generator set monitoring and control system. The control provides a simple operator interface to the generator set, auto/ manual and remote start/stop control and shutdown fault indication. The integration of all control functions into a single control provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet the harsh environment in which gensets are typically applied.
• The PowerStart generator set control is suitable for use on a wide range of generator sets in nonparalleling applications. It is suitable for use with reconnectable or non-reconnectable generators, can be configured for either 50 Hz or 60 Hz and voltage and power connection from 190-600 VAC line-to-line.
• This control includes an intuitive operator interface that allows for complete genset control as well as system metering, fault annunciation, maintenance alarm, over imbalance current, configuration and diagnostics. The interface includes seven generator set status LED lamps with both internationally accepted symbols and English text to comply with customer needs. The interface also includes an LED backlit LCD display with tactile-feel softswitches for easy operation and screen navigation. The manual/auto/stop switch function is integrated into the interface panel.
• All data on the control can be viewed by scrolling through screens with the navigation keys. The control displays the current active fault and a timeordered history of the five previous faults.
• Power for this control is derived from the generator set starting batteries and functions over a voltage range from 8VDC to 16 VDC.
CUMMINS ATS-207 C330D5 ATS PANEL MAXIMUM 630A
CUMMINS ATS-207 C400D5 ATS PANEL MAXIMUM 630A
- Phase
- Three phase
- Maximum power three phase (KW)
- 240
- Continuous power three phase (KW)
- 220
- Maximum power three phase (KVA)
- 300
- Continuous power three phase (KVA)
- 275
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 400
- Sockets configuration
- Terminal box
- Engine
- 4 stroke
- Emissions Regulations
- Stationary Use
- Engine rpm (rpm)
- 1500
- Speed governor
- Mechanical
- Number cylinders
- 6
- Cylinders' position
- In line
- Cooling
- Air
- Poles
- 4
- Bore x stroke (mm)
- 91.4x127
- Length (mm)
- 4250
- Width (mm)
- 1438
- Height (mm)
- 2348
- Dry weight (Kg)
- 4300
- Silenced
- Yes
- Brushes
- No
- Product type
- Generator
- Control unit
- PowerStart 600
- ATS Switch device
- Optional
- Type of alternator
- Constant Speed
- Engine manufacturer
- Cummins
- Precision of voltage regulation
- ± 2,5%