Phase Type: Single-phase / Three-phase
Single-phase Continuous Power: 5.0KVA / 4.0KW
Single-phase Maximum Power: 5.6KVA / 4.5KW
Three-phase Continuous Power: 15.0KVA / 12.0KW
Three-phase Maximum Power: 17.0KVA / 13. 0KW
Motor: Kohler KDW1603
Starting: Electric
Power Supply: Diesel
Panel Sockets: 1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 16A 400V - 1 x 32A 400V
Voltage: 230 / 400 V
Frequency: 50 Hz
Motor RPM: 1500 rpm
Tank capacity: 50 l
Autonomy @ 75%: 14 h fixed revolutions
Voltage regulator: AVR
Sound pressure @7m: 67 dBa
Length (mm): 1802
Width (mm): 752
Height (mm): 1130
Dry weight (Kg): 558

Technical features
Phase
Single phase / Three phase
Maximum power single phase (KW)
4.5
Continuous power single phase (KW)
4
Maximum power single phase (KVA)
5.6
Continuous power single phase (KVA)
5
Maximum power three phase (KW)
13.0
Continuous power three phase (KW)
12.0
Maximum power three phase (KVA)
17.0
Continuous power three phase (KVA)
15.0
Fuel
Diesel
Frequency (Hz)
50
Voltage (V)
230 / 400
Sockets configuration
1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 16A 400V - 1 x 32A 400V
Engine
Kohler KDW1603
Engine rpm (rpm)
1500
Starting system
Electric
Cooling
Water
Poles
2
Fuel tank capacity (L)
50
Running time (h)
14
Acoustic pressure
67 dB(A) at 7 m
Length (mm)
1802
Width (mm)
752
Height (mm)
1130
Dry weight (Kg)
558
Silenced
Yes
Super silenced
Yes
ATS Switch device
Optional
Voltage regulator
AVR
Engine manufacturer
Kohler
Details

GENMAC INFINITY G15KS THREE-PHASE GENERATOR 17,0KVA

The generator GENMAC Infinity G15KS three-phase is equipped with a Kohler diesel-powered engine capable of delivering a power of 17,0KVA with AVR voltage regulator.

The generator is equipped with an oversized Kohler engine capable of delivering a continuous power of 14.0KVA and a maximum power of 17,0KVA. Thanks to the 50l tank the Genmac Infinity generator has an autonomy of up to 14 hours of work.

The Genmac generator silenced has been realized with a high performance frame to minimize the sound pressure. The frame is made with steel plates made according to UNI S235JR standards, complete with rubber anti-vibration supports. In order to improve the handling before use, at the base of the generator there are bilateral steel pockets for forklift trucks, which allows lifting from all sides, and on the top of the generator there is a hook for central lifting.

The 17,0KVA generator is complete with 4 doors that allow easy access for ordinary or extraordinary maintenance. In order to make this Genmac generator as quiet as possible, 100% recyclable, fireproof, self-extinguishing, fireproof, washable, class 1 reaction to fire, mechanically fixed to the frame.

The control panel of the generator is made of metal with a rear cover to protect against the weather and is provided with a dedicated area to facilitate the electrical connection to the load.
All units and components are factory tested, built in prototype, and
header production. A specific control procedure during the various phases
production guarantees long life and reliability.

AVR Voltage Regulator

The AVR is essential to make the generator work at its best, in fact it all needs an electronic control system, an AVR in fact, which ensures the proper functioning of the machine and the electrical network behind it.

The purpose of the AVR, in a current generator, is to keep the output stable. And if its operation is very simple when resistive loads are fed, more complex is the matter in case of mainly inductive loads: the delayed phase shift current counteracts the inductor magnetic field, causing a voltage drop at the alternator terminals; to compensate for this phenomenon, the AVR intervenes automatically by increasing the excitation current, until the returns to the nominal value. If the load is capacitive, the current acts as a magnetizer for the inductor causing an increase in voltage exit, and the AVR intervenes by reducing the excitation current.

TECHNICAL CHARACTERISTICS OF GENERATOR GENMAC Infinity G15KS 17,0KVA

Phase Type: Singlephase / Threephase
Singlephase Continuous Power: 5.0KVA / 4.0KW
Singlephase Maximum Power: 5.6KVA / 4.5KW
Threephase Continuous Power: 15.0KVA / 12.0KW
Threephase Maximum Power: 17.0KVA / 13. 0KW
Motor: Kohler KDW1603
Starting: Electric
Power Supply: Diesel
Panel Sockets: 1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 16A 400V - 1 x 32A 400V
Voltage: 230 / 400 V
Frequency: 50 Hz
Motor RPM: 1500 rpm
Tank capacity: 50 l
Autonomy @ 75%: 14 h fixed revolutions
Voltage regulator: AVR
Sound pressure @7m: 67 dBa
Length (mm): 1802
Width (mm): 752
Height (mm): 1130
Dry weight (Kg): 558

If you are looking for another product then you can consult other terrestrial generators in our catalog.

Images and technical data are not binding.

Technical Sheet / Manuals
Related Accessories
Ask for availability
Add to wishlist
Download PDF
Ask a question
Product: GENMAC Infinity G15KS GENERATOR 17,0KVA
Offer on letterhead
Product: GENMAC Infinity G15KS GENERATOR 17,0KVA
Technical features
Phase
Single phase / Three phase
Maximum power single phase (KW)
4.5
Continuous power single phase (KW)
4
Maximum power single phase (KVA)
5.6
Continuous power single phase (KVA)
5
Maximum power three phase (KW)
13.0
Continuous power three phase (KW)
12.0
Maximum power three phase (KVA)
17.0
Continuous power three phase (KVA)
15.0
Fuel
Diesel
Frequency (Hz)
50
Voltage (V)
230 / 400
Sockets configuration
1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 16A 400V - 1 x 32A 400V
Engine
Kohler KDW1603
Engine rpm (rpm)
1500
Starting system
Electric
Cooling
Water
Poles
2
Fuel tank capacity (L)
50
Running time (h)
14
Acoustic pressure
67 dB(A) at 7 m
Length (mm)
1802
Width (mm)
752
Height (mm)
1130
Dry weight (Kg)
558
Silenced
Yes
Super silenced
Yes
ATS Switch device
Optional
Voltage regulator
AVR
Engine manufacturer
Kohler