<iframe src="https://www.googletagmanager.com/ns.html?id=GTM-PHW6DPD" height="0" width="0" style="display:none;visibility:hidden">

GENMAC MAGNUM G500VS-E3 THREE-PHASE 500 KVA DIESEL - MOTOR VOLVO PENTA STAGE 3A

GENMAC MAGNUM G500VS-E3 500 KVA DIESEL
search
  • GENMAC MAGNUM G500VS-E3 500 KVA DIESEL
  • GENMAC MAGNUM G500VS-E3 500 KVA DIESEL
GENMAC
MAGNUM G500VS-E3-STAGE 3A-AVR
New product

Phase Type: Single-phase / Three-phase
Maximum power LTP: 550 KVA
Maximum power LTP: 440 KW
Continuous power PRP: 500 KVA
Continuous power PRP: 400 KW
Fuel: Diesel
Frequency: 50 Hz
Voltage: 230 / 400 V
Engine: Volvo-Penta TAD1651GE
Engine rpm: 1500 rpm
Cooling: Water
Length: 4500 mm
Width: 1666 mm
Height: 2250 mm
Weight: 2255 Kg
Super silenced
AVR

Technical features
Phase
Single phase / Three phase
Maximum power three phase (KW)
440
Continuous power three phase (KW)
400
Maximum power three phase (KVA)
550
Continuous power three phase (KVA)
500
Fuel
Diesel
Frequency (Hz)
50
Voltage (V)
230 / 400
Emissions Regulations
Stage 3A
Engine rpm (rpm)
1500
Speed governor
Electronic
Engine capacity (cm³)
16120
Number cylinders
6
Oil capacity (L)
48
Cooling
Water
Alternator
Synchronous, self-excited
Length (mm)
4500
Width (mm)
1666
Height (mm)
2250
Dry weight (Kg)
2255
AVR
Yes
Silenced
Yes
Super silenced
Yes
Product type
Generator
ATS Switch device
No
Voltage regulator
AVR
Engine manufacturer
Volvo
Details

GENMAC MAGNUM G500VS-E3

The GENMAC MAGNUM G500VS-E3 is a 500 KVA super-silenced single-phase/three-phase diesel generator with Stamford alternator and AVR voltage regulator.
Thanks to its diesel fuel supply, the GENMAC MAGNUM G500VS-E3 can only consume 10.52 m³/h at full load and has a low environmental impact, making it one of the best in its class.
The long life and reliability of the GENMAC MAGNUM G500VS-E3 is due to a special control procedure during the various stages of production.
The GENMAC MAGNUM G500VS-E3 is suitable for applications in different contexts such as: hospitals, industries, shopping malls, hotels, airports, banks, universities, stadiums, offices, etc.

The Stage 3A engine allows the use of the generator set also for mobile use, for example for roadworks and rental services.

Control panel features

QT2A-4520

Self-standing tower with IP65 metal box
Circuit breaker
AMF controller DSE4520
- Voltmeter, Frequencymeter, Ammeter
- Generator power (kW, kV Ar, kV A & pf) monitoring
- Hour meter
- Fuel level meter
- Overload (kW & kV Ar) protection
- Low oil pressure protection
- High coolant temperature protection
- Low fuel level protection
- Battery charger alternator fault
- Rpm protection
Emergency stop button
Audible alarm
Terminal board for ATS connection
Can Bus reading Port (if standard on the engine)
Battery charger
On/off switch

Images and technical data are not binding.

List price
120.663,80 € tax incl.
98.904,75 € tax excl.
Discounted Price
65.603,85 € tax incl.
53.773,65 € tax excl.
Voltage Regulator
Ask for availability
Add to wishlist
Download PDF
Ask a question
Product: GENMAC MAGNUM G500VS-E3 THREE-PHASE 500 KVA DIESEL - MOTOR VOLVO PENTA STAGE 3A
Offer on letterhead
Product: GENMAC MAGNUM G500VS-E3 THREE-PHASE 500 KVA DIESEL - MOTOR VOLVO PENTA STAGE 3A
Technical features
Phase
Single phase / Three phase
Maximum power three phase (KW)
440
Continuous power three phase (KW)
400
Maximum power three phase (KVA)
550
Continuous power three phase (KVA)
500
Fuel
Diesel
Frequency (Hz)
50
Voltage (V)
230 / 400
Emissions Regulations
Stage 3A
Engine rpm (rpm)
1500
Speed governor
Electronic
Engine capacity (cm³)
16120
Number cylinders
6
Oil capacity (L)
48
Cooling
Water
Alternator
Synchronous, self-excited
Length (mm)
4500
Width (mm)
1666
Height (mm)
2250
Dry weight (Kg)
2255
AVR
Yes
Silenced
Yes
Super silenced
Yes
Product type
Generator
ATS Switch device
No
Voltage regulator
AVR
Engine manufacturer
Volvo
Details