GENMAC MAGNUM G500VS-E3 THREE-PHASE 500 KVA DIESEL - MOTOR VOLVO PENTA STAGE 3A
Phase Type: Single-phase / Three-phase
Maximum power LTP: 550 KVA
Maximum power LTP: 440 KW
Continuous power PRP: 500 KVA
Continuous power PRP: 400 KW
Fuel: Diesel
Frequency: 50 Hz
Voltage: 230 / 400 V
Engine: Volvo-Penta TAD1651GE
Engine rpm: 1500 rpm
Cooling: Water
Length: 4500 mm
Width: 1666 mm
Height: 2250 mm
Weight: 2255 Kg
Super silenced
AVR
- Phase
- Single phase / Three phase
- Maximum power three phase (KW)
- 440
- Continuous power three phase (KW)
- 400
- Maximum power three phase (KVA)
- 550
- Continuous power three phase (KVA)
- 500
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Emissions Regulations
- Stage 3A
- Engine rpm (rpm)
- 1500
- Speed governor
- Electronic
- Engine capacity (cm³)
- 16120
- Number cylinders
- 6
- Oil capacity (L)
- 48
- Cooling
- Water
- Alternator
- Synchronous, self-excited
- Length (mm)
- 4500
- Width (mm)
- 1666
- Height (mm)
- 2250
- Dry weight (Kg)
- 2255
- AVR
- Yes
- Silenced
- Yes
- Super silenced
- Yes
- Product type
- Generator
- ATS Switch device
- No
- Voltage regulator
- AVR
- Engine manufacturer
- Volvo
GENMAC MAGNUM G500VS-E3
The GENMAC MAGNUM G500VS-E3 is a 500 KVA super-silenced single-phase/three-phase diesel generator with Stamford alternator and AVR voltage regulator.
Thanks to its diesel fuel supply, the GENMAC MAGNUM G500VS-E3 can only consume 10.52 m³/h at full load and has a low environmental impact, making it one of the best in its class.
The long life and reliability of the GENMAC MAGNUM G500VS-E3 is due to a special control procedure during the various stages of production.
The GENMAC MAGNUM G500VS-E3 is suitable for applications in different contexts such as: hospitals, industries, shopping malls, hotels, airports, banks, universities, stadiums, offices, etc.
The Stage 3A engine allows the use of the generator set also for mobile use, for example for roadworks and rental services.
Control panel features
QT2A-4520
Self-standing tower with IP65 metal box Circuit breaker AMF controller DSE4520 - Voltmeter, Frequencymeter, Ammeter - Generator power (kW, kV Ar, kV A & pf) monitoring - Hour meter - Fuel level meter - Overload (kW & kV Ar) protection - Low oil pressure protection - High coolant temperature protection - Low fuel level protection - Battery charger alternator fault - Rpm protection Emergency stop button Audible alarm Terminal board for ATS connection Can Bus reading Port (if standard on the engine) Battery charger On/off switchImages and technical data are not binding.
- Phase
- Single phase / Three phase
- Maximum power three phase (KW)
- 440
- Continuous power three phase (KW)
- 400
- Maximum power three phase (KVA)
- 550
- Continuous power three phase (KVA)
- 500
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Emissions Regulations
- Stage 3A
- Engine rpm (rpm)
- 1500
- Speed governor
- Electronic
- Engine capacity (cm³)
- 16120
- Number cylinders
- 6
- Oil capacity (L)
- 48
- Cooling
- Water
- Alternator
- Synchronous, self-excited
- Length (mm)
- 4500
- Width (mm)
- 1666
- Height (mm)
- 2250
- Dry weight (Kg)
- 2255
- AVR
- Yes
- Silenced
- Yes
- Super silenced
- Yes
- Product type
- Generator
- ATS Switch device
- No
- Voltage regulator
- AVR
- Engine manufacturer
- Volvo