GENMAC QUEEN G120JS-E3 THREE-PHASE 121 KVA DIESEL - MOTOR JOHN-DEERE STAGE 3A
Phase Type: Single-phase / Three-phase
Maximum power LTP: 134 KVA
Maximum power LTP: 107 KW
Continuous power PRP: 121 KVA
Continuous power PRP: 97 KW
Fuel: Diesel
Frequency: 50 Hz
Voltage: 230 / 400 V
Engine: John-Deere 4045HFU82-120
Engine rpm: 1500 rpm
Cooling: Water
Length: 2950 mm
Width: 1056 mm
Height: 1900 mm
Weight: 1719 Kg
Super silenced
AVR
- Phase
- Single phase / Three phase
- Maximum power three phase (KW)
- 107
- Continuous power three phase (KW)
- 97
- Maximum power three phase (KVA)
- 134
- Continuous power three phase (KVA)
- 121
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Emissions Regulations
- Stage 3A
- Engine rpm (rpm)
- 1500
- Speed governor
- Electronic
- Engine capacity (cm³)
- 4500
- Number cylinders
- 4
- Oil capacity (L)
- 15
- Cooling
- Water
- Alternator
- Mecc Alte
- Width (mm)
- 1056
- Height (mm)
- 1900
- Dry weight (Kg)
- 1720
- AVR
- Yes
- Silenced
- Yes
- Super silenced
- Yes
- Product type
- Generator
- ATS Switch device
- No
- Voltage regulator
- AVR
- Engine manufacturer
- John Deere
GENMAC QUEEN G120JS-E3
The GENMAC QUEEN G120JS-E3 is a 121 KVA super-silenced single-phase/three-phase diesel generator with Mecc Alte alternator and AVR voltage regulator.
Thanks to its diesel fuel supply, the GENMAC QUEEN G120JS-E3 can only consume 2.9 m³/h at full load and has a low environmental impact, making it one of the best in its class.
The long life and reliability of the GENMAC QUEEN G120JS-E3 is due to a special control procedure during the various stages of production.
The GENMAC QUEEN G120JS-E3 is suitable for applications in different contexts such as: hospitals, industries, shopping malls, hotels, airports, banks, universities, stadiums, offices, etc.
The Stage 3A engine allows the use of the generator set also for mobile use, for example for roadworks and rental services.
Control panel features
QT2A-4520
Self-standing tower with IP65 metal box Circuit breaker AMF controller DSE4520 - Voltmeter, Frequencymeter, Ammeter - Generator power (kW, kV Ar, kV A & pf) monitoring - Hour meter - Fuel level meter - Overload (kW & kV Ar) protection - Low oil pressure protection - High coolant temperature protection - Low fuel level protection - Battery charger alternator fault - Rpm protection Emergency stop button Audible alarm Terminal board for ATS connection Can Bus reading Port (if standard on the engine) Battery charger On/off switchImages and technical data are not binding.
- Phase
- Single phase / Three phase
- Maximum power three phase (KW)
- 107
- Continuous power three phase (KW)
- 97
- Maximum power three phase (KVA)
- 134
- Continuous power three phase (KVA)
- 121
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Emissions Regulations
- Stage 3A
- Engine rpm (rpm)
- 1500
- Speed governor
- Electronic
- Engine capacity (cm³)
- 4500
- Number cylinders
- 4
- Oil capacity (L)
- 15
- Cooling
- Water
- Alternator
- Mecc Alte
- Width (mm)
- 1056
- Height (mm)
- 1900
- Dry weight (Kg)
- 1720
- AVR
- Yes
- Silenced
- Yes
- Super silenced
- Yes
- Product type
- Generator
- ATS Switch device
- No
- Voltage regulator
- AVR
- Engine manufacturer
- John Deere