<iframe src="https://www.googletagmanager.com/ns.html?id=GTM-PHW6DPD" height="0" width="0" style="display:none;visibility:hidden">

GENMAC Queen-Rent G130IS-M GENERATOR 143,0KVA

GENMAC Urban G15000KS Diesel Generating set 15 KVA 12 KW Silenced
search
  • GENMAC Urban G15000KS Diesel Generating set 15 KVA 12 KW Silenced
GENMAC
Queen-Rent G130IS-M
New product

OUT OF PRODUCTION

Voltage regulator : AVR
Power supply: Diesel
Starting: Electric
Three-phase
Continuous output: 104,0KW
Continuous output: 130,0KVA
Maximum Output: 114,0KW
Maximum output: 143,0KVA
Voltage: 400V
Frequency: 50 Hz
1500 revolutions per minute
Tank capacity: 270 l
Autonomy @ 75%: 12 h fixed revolutions
Sound pressure @7m: 70 dBa
Length (mm): 3150
Width (mm): 1056
Height (mm): 1900
Dry weight (Kg): 1679

Technical features
Phase
Three phase
Maximum power three phase (KW)
104.0
Continuous power three phase (KW)
114.0
Maximum power three phase (KVA)
143.0
Continuous power three phase (KVA)
130.0
Fuel
Diesel
Frequency (Hz)
50
Voltage (V)
400
Engine
FPT (IVECO) N45SM3, 4 stroke, turbo-aftercooler
Engine rpm (rpm)
1500
Starting system
Electric
Cooling
Water
Poles
2
Fuel tank capacity (L)
270
Running time (h)
12
Acoustic pressure
70 dB(A)
Length (mm)
3150
Width (mm)
1056
Height (mm)
1900
Dry weight (Kg)
1679
Silenced
Yes
Super silenced
No
Voltage regulator
AVR
Engine manufacturer
FPT Iveco
Details

GENMAC Queen-Rent G130IS-M THREE-PHASE GENERATOR 143,0KVA

The generator GENMAC Queen-Rent G130IS-M three-phase is equipped with a Iveco diesel-powered engine capable of delivering a power of 143,0KVA with AVR voltage regulator.

The generator is equipped with an oversized Iveco engine capable of delivering a continuous power of 130.0KVA and a maximum power of 143,0KVA. Thanks to the 270 l tank the Genmac Infinity generator has an autonomy of up to 12 hours of work.

The 143,0KVA generator is complete with doors that allow easy access for ordinary or extraordinary maintenance. In order to make this Genmac generator as quiet as possible, 100% recyclable, fireproof, self-extinguishing, fireproof, washable, class 1 reaction to fire, mechanically fixed to the frame.

The silenced generator is specific for mobile and rental applications. Easy to use and move. It mounts the latest generation engine with low emission level, for an energy that respects the environment.

Control panel

The control panel consists of:

No. 1 CEE 32A 400V
No. 1 CEE 16A 400V
No. 2 CEE 16A 230V
No. 1 Schuko 16A 230V
Thermal Circuit Breaker
Thermal-magnetic switch
Controller DSE4510
- Voltmeter, Frequency meter, Ammeter
- Generator power reading (kW, kV Ar, kV A & pf)
- Hour meter
- Fuel tool
- Overload protection (kW & kV Ar)
- Low oil pressure protection
- High temperature refrigerant protection
- Low fuel level protection
- Battery charger alternator failure
- Off-rotation protections
- Oil pressure and engine temperature reading
Analog fuel level instrument
Emergency Stop Button
Connector for Remote Start/Automatic Square
On/off switch

AVR Voltage Regulator

The AVR is essential to make the generator work at its best, in fact it all needs an electronic control system, an AVR in fact, which ensures the proper functioning of the machine and the electrical network behind it.

The purpose of the AVR, in a current generator, is to keep the output stable. And if its operation is very simple when resistive loads are fed, more complex is the matter in case of mainly inductive loads: the delayed phase shift current counteracts the inductor magnetic field, causing a voltage drop at the alternator terminals; to compensate for this phenomenon, the AVR intervenes automatically by increasing the excitation current, until the returns to the nominal value. If the load is capacitive, the current acts as a magnetizer for the inductor causing an increase in voltage exit, and the AVR intervenes by reducing the excitation current.

TECHNICAL CHARACTERISTICS OF GENERATOR GENMAC Queen-Rent G130IS-M 143,0KVA

Voltage regulator : AVR
Power supply: Diesel
Starting: Electric
Three-phase
Continuous output: 104,0KW
Continuous output: 130,0KVA
Maximum Output: 114,0KW
Maximum output: 143,0KVA
Voltage: 400V
Frequency: 50 Hz
1500 revolutions per minute
Tank capacity: 270 l 
Autonomy @ 75%: 12 h fixed revolutions
Sound pressure @7m: 70 dBa 
Length (mm): 3150
Width (mm): 1056
Height (mm): 1900
Dry weight (Kg): 1679

If you are looking for another product then you can consult other terrestrial generators in our catalog.

Images and technical data are not binding.

Technical Sheet / Manuals
Related Accessories
Ask for availability
Add to wishlist
Download PDF
Ask a question
Product: GENMAC Queen-Rent G130IS-M GENERATOR 143,0KVA
Offer on letterhead
Product: GENMAC Queen-Rent G130IS-M GENERATOR 143,0KVA
Technical features
Phase
Three phase
Maximum power three phase (KW)
104.0
Continuous power three phase (KW)
114.0
Maximum power three phase (KVA)
143.0
Continuous power three phase (KVA)
130.0
Fuel
Diesel
Frequency (Hz)
50
Voltage (V)
400
Engine
FPT (IVECO) N45SM3, 4 stroke, turbo-aftercooler
Engine rpm (rpm)
1500
Starting system
Electric
Cooling
Water
Poles
2
Fuel tank capacity (L)
270
Running time (h)
12
Acoustic pressure
70 dB(A)
Length (mm)
3150
Width (mm)
1056
Height (mm)
1900
Dry weight (Kg)
1679
Silenced
Yes
Super silenced
No
Voltage regulator
AVR
Engine manufacturer
FPT Iveco
Details
Technical Sheet / Manuals