New product

Phase Type: Single Phase / Three Phase
Single Phase Continuous Power: 13.3KVA / 10.6KW
Single Phase Maximum Power: 14.6KVA / 11. 7KW
Three-phase Continuous Power: 40KVA / 32KW
Three-phase Maximum Power: 44KVA / 35KW
Motor: Kohler KDI2504TM-40
Starting: Electric
Power Supply: Diesel
Panel Sockets: 1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 32A 400V - 1 x 63A 400V
Voltage: 230 / 400 V
Frequency: 50 Hz
Motor revolutions: 1500 rpm
Tank capacity: 50 l
Autonomy @ 75%: 6 h fixed revolutions
Voltage regulator: AVR
Acoustic pressure @7m: 65 dBa
Length (mm): 2000
Width (mm): 960
Height (mm): 1263
Dry weight (Kg): 1247

Technical features
Phase
Single phase / Three phase
Maximum power single phase (KW)
11.7
Continuous power single phase (KW)
10.6
Maximum power single phase (KVA)
14.6
Continuous power single phase (KVA)
13.3
Maximum power three phase (KW)
35,0
Continuous power three phase (KW)
32.0
Maximum power three phase (KVA)
44.0
Continuous power three phase (KVA)
40.0
Fuel
Diesel
Frequency (Hz)
50
Voltage (V)
230 / 400
Sockets configuration
1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 32A 400V - 1 x 63A 400V
Engine
Kohler KDI 2504 M
Engine rpm (rpm)
1500
Starting system
Electric
Cooling
Water
Poles
2
Fuel tank capacity (L)
50
Running time (h)
6
Acoustic pressure
65 dB(A) at 7 m
Length (mm)
2000
Width (mm)
960
Height (mm)
1263
Dry weight (Kg)
1247
Silenced
Yes
Super silenced
Yes
ATS Switch device
Optional
Voltage regulator
AVR
Engine manufacturer
Kohler
Details

GENMAC STONE G40KS THREE-PHASE GENERATOR 44,0KVA

The generator GENMAC Stone G40KS three-phase is equipped with a Kohler diesel-powered engine capable of delivering a power of 44,0KVA with AVR voltage regulator.

The generator is equipped with an oversized Kohler engine capable of delivering a continuous power of 40,0KVA and a maximum power of 44,0KVA. Thanks to the 50l tank the Genmac Infinity generator has an autonomy of up to 6 hours of work.

The Genmac generator silenced has been realized with a high performance frame to minimize the sound pressure. The frame is made with steel plates made according to UNI S235JR standards, complete with rubber anti-vibration supports. In order to improve the handling before use, at the base of the generator there are bilateral steel pockets for forklift trucks, which allows lifting from all sides, and on the top of the generator there is a hook for central lifting.

The 44,0KVA generator is complete with 3 doors that allow easy access for ordinary or extraordinary maintenance. In order to make this Genmac generator as quiet as possible, 100% recyclable, fireproof, self-extinguishing, fireproof, washable, class 1 reaction to fire, mechanically fixed to the frame.

AVR Voltage Regulator

The AVR is essential to make the generator work at its best, in fact it all needs an electronic control system, an AVR in fact, which ensures the proper functioning of the machine and the electrical network behind it.

The purpose of the AVR, in a current generator, is to keep the output stable. And if its operation is very simple when resistive loads are fed, more complex is the matter in case of mainly inductive loads: the delayed phase shift current counteracts the inductor magnetic field, causing a voltage drop at the alternator terminals; to compensate for this phenomenon, the AVR intervenes automatically by increasing the excitation current, until the returns to the nominal value. If the load is capacitive, the current acts as a magnetizer for the inductor causing an increase in voltage exit, and the AVR intervenes by reducing the excitation current.

TECHNICAL CHARACTERISTICS OF GENERATOR GENMAC Stone G40KS 44,0KVA

Phase Type: SinglePhase / ThreePhase
SinglePhase Continuous Power: 13.3KVA / 10.6KW
SinglePhase Maximum Power: 14.6KVA / 11. 7KW
Threephase Continuous Power: 40KVA / 32KW
Threephase Maximum Power: 44KVA / 35KW
Motor: Kohler KDI2504TM-40
Starting: Electric
Power Supply: Diesel
Panel Sockets: 1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 32A 400V - 1 x 63A 400V
Voltage: 230 / 400 V
Frequency: 50 Hz
Motor revolutions: 1500 rpm
Tank capacity: 50 l
Autonomy @ 75%: 6 h fixed revolutions
Voltage regulator: AVR
Acoustic pressure @7m: 65 dBa
Length (mm): 2000
Width (mm): 960
Height (mm): 1263
Dry weight (Kg): 1247

If you are looking for another product then you can consult other terrestrial generators in our catalog.

Images and technical data are not binding.

Technical Sheet / Manuals
Related Accessories
List price
27.077,90 € tax incl.
22.195,00 € tax excl.
Discounted Price
13.739,64 € tax incl.
11.262,00 € tax excl.
Quantity

loader
400,00 € shipped to Italy

Calculate Shipping Cost
Add to wishlist
Download PDF
Ask a question
Product: GENMAC Stone G40KS GENERATOR 44,0KVA
Offer on letterhead
Product: GENMAC Stone G40KS GENERATOR 44,0KVA
Technical features
Phase
Single phase / Three phase
Maximum power single phase (KW)
11.7
Continuous power single phase (KW)
10.6
Maximum power single phase (KVA)
14.6
Continuous power single phase (KVA)
13.3
Maximum power three phase (KW)
35,0
Continuous power three phase (KW)
32.0
Maximum power three phase (KVA)
44.0
Continuous power three phase (KVA)
40.0
Fuel
Diesel
Frequency (Hz)
50
Voltage (V)
230 / 400
Sockets configuration
1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 32A 400V - 1 x 63A 400V
Engine
Kohler KDI 2504 M
Engine rpm (rpm)
1500
Starting system
Electric
Cooling
Water
Poles
2
Fuel tank capacity (L)
50
Running time (h)
6
Acoustic pressure
65 dB(A) at 7 m
Length (mm)
2000
Width (mm)
960
Height (mm)
1263
Dry weight (Kg)
1247
Silenced
Yes
Super silenced
Yes
ATS Switch device
Optional
Voltage regulator
AVR
Engine manufacturer
Kohler
Details