GENMAC Urban G10PS GENERATOR 9,9KVA
OUT OF PRODUCTION
Voltage regulator : AVR
Power supply: Diesel
Starting: Electric
Three-phase
Maximum Output: 7,2KW
Maximum output: 9,0KVA
Maximum Output: 7,9KW
Maximum Output: 9,9KVA
Voltage: 400V
Frequency: 50 Hz
1500 revolutions per minute
Tank capacity: 50 l
Autonomy @ 75%: 25 h fixed revolutions
Sound pressure @7m: 67 dBa
Length (mm): 1457
Width (mm): 710
Height (mm): 1060
Dry weight (Kg): 415
- Phase
- Three phase
- Maximum power three phase (KW)
- 7.9
- Continuous power three phase (KW)
- 7.2
- Maximum power three phase (KVA)
- 9.9
- Continuous power three phase (KVA)
- 9.0
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 400
- Engine
- Perkins 403A-11G1
- Engine rpm (rpm)
- 1500
- Starting system
- Electric
- Cooling
- Water
- Poles
- 2
- Fuel tank capacity (L)
- 50
- Running time (h)
- 25
- Acoustic pressure
- 67 dB(A)
- Length (mm)
- 1475
- Width (mm)
- 710
- Height (mm)
- 1060
- Dry weight (Kg)
- 415
- Silenced
- Yes
- Super silenced
- No
- Voltage regulator
- AVR
- Engine manufacturer
- Perkins
GENMAC URBAN G10PS THREE-PHASE GENERATOR 9,9KVA
The generator GENMAC Urban G10PS three-phase is equipped with a Perkins diesel-powered engine capable of delivering a power of 9,9KVA with AVR voltage regulator.
High quality professional silenced diesel generator of the construction series, Genmac Urban with power of 9,9KVA, produced by Italian company Genmac. The generator is equipped with an oversized engine with water cooling and a practical electric starter.
For this line of generators is possible the supply of a differential protection circuit, in addition is possible the supply of trolleys for the handling of the unit. Genmac 9,9KVA current generators are used in carpentry, construction, greenhouses, road construction sites, mobile stations, homes, etc..
Genmac Urban power generators are highly reliable machines, built with quality components to be used in the professional field, where reliability is fundamental.
Gen Genmac generators are supplied with AVR card, tank with collection tank and central lifting hook as standard on all models.
AVR Voltage Regulator
The AVR is essential to make the generator work at its best, in fact it all needs an electronic control system, an AVR in fact, which ensures the proper functioning of the machine and the electrical network behind it.
The purpose of the AVR, in a current generator, is to keep the output stable. And if its operation is very simple when resistive loads are fed, more complex is the matter in case of mainly inductive loads: the delayed phase shift current counteracts the inductor magnetic field, causing a voltage drop at the alternator terminals; to compensate for this phenomenon, the AVR intervenes automatically by increasing the excitation current, until the returns to the nominal value. If the load is capacitive, the current acts as a magnetizer for the inductor causing an increase in voltage exit, and the AVR intervenes by reducing the excitation current.
TECHNICAL CHARACTERISTICS OF GENERATOR GENMAC Urban G10PS 9,9KVA
Voltage regulator : AVR
Power supply: Diesel
Starting: Electric
Three-phase
Maximum Output: 7,2KW
Maximum output: 9,0KVA
Maximum Output: 7,9KW
Maximum Output: 9,9KVA
Voltage: 400V
Frequency: 50 Hz
1500 revolutions per minute
Tank capacity: 50 l
Autonomy @ 75%: 25 h fixed revolutions
Sound pressure @7m: 67 dBa
Length (mm): 1457
Width (mm): 710
Height (mm): 1060
Dry weight (Kg): 415
If you are looking for another product then you can consult other terrestrial generators in our catalog.
Images and technical data are not binding.
GENMAC AUTOMATIC TRANSFER SWITCH ATS-L4520 2P 50Hz 1PH 230V 40A
Earth fault breaker Urban three phase
- Phase
- Three phase
- Maximum power three phase (KW)
- 7.9
- Continuous power three phase (KW)
- 7.2
- Maximum power three phase (KVA)
- 9.9
- Continuous power three phase (KVA)
- 9.0
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 400
- Engine
- Perkins 403A-11G1
- Engine rpm (rpm)
- 1500
- Starting system
- Electric
- Cooling
- Water
- Poles
- 2
- Fuel tank capacity (L)
- 50
- Running time (h)
- 25
- Acoustic pressure
- 67 dB(A)
- Length (mm)
- 1475
- Width (mm)
- 710
- Height (mm)
- 1060
- Dry weight (Kg)
- 415
- Silenced
- Yes
- Super silenced
- No
- Voltage regulator
- AVR
- Engine manufacturer
- Perkins