GENMAC Urban G11600KS-M5 GENERATOR 11,8KVA
Phase Type: Single-Phase/Three-Phase
Single-Phase Continuous Power: 3.5KVA / 2.8KW
Single-Phase Maximum Power: 4KVA / 3.2KW
Three-Phase Continuous Power: 10.6KVA / 8.5KW
Three-Phase Maximum Power: 11.8KVA / 9.4KW
Motor: Kohler KDW702
Emissions Standard: Stage V
Starting: Electric
Power Supply: Diesel
Receptacle Panel: 1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 16A 400V - 1 x 32A 400V
Voltage: 230 / 400 V
Frequency: 50 Hz
Motor RPM: 3000 rpm
Tank Capacity: 50 l
Autonomy @ 75%: 17 h fixed rpm
Voltage regulator : AVR
Sound pressure @7m: 68 dBa
Length (mm): 1475
Width (mm): 710
Height (mm): 1060
Dry weight (Kg): 400
- Phase
- Single phase / Three phase
- Maximum power single phase (KW)
- 3.2
- Continuous power single phase (KW)
- 2.8
- Maximum power single phase (KVA)
- 4
- Continuous power single phase (KVA)
- 3.5
- Maximum power three phase (KW)
- 9.4
- Continuous power three phase (KW)
- 8.5
- Maximum power three phase (KVA)
- 11.8
- Continuous power three phase (KVA)
- 10.6
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Sockets configuration
- 1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 16A 400V - 1 x 32A 400V
- Engine
- Kohler KDW702
- Emissions Regulations
- Stage 5
- Engine rpm (rpm)
- 3000
- Starting system
- Electric
- Cooling
- Water
- Poles
- 2
- Fuel tank capacity (L)
- 50
- Running time (h)
- 17
- Acoustic pressure
- 68 dB(A) at 7 m
- Length (mm)
- 1475
- Width (mm)
- 710
- Height (mm)
- 1060
- Dry weight (Kg)
- 400
- Silenced
- Yes
- Super silenced
- Yes
- ATS Switch device
- Optional
- Voltage regulator
- AVR
- Engine manufacturer
- Kohler
GENMAC URBAN G11600KS-M5 SINGLE-PHASE / THREE-PHASE GENERATOR 11,8KVA
The generator GENMAC Urban G11600KS-M5 Single-phase / Three-phase is equipped with a Kohler KDW702 Stage V diesel-powered engine capable of delivering a power of 11,8KVA with AVR voltage regulator.
The high quality professional silenced diesel generator of the construction series, Genmac Urban with power of 11,8KVA, produced by Italian company Genmac. The generator is equipped with an oversized engine with water cooling and a practical electric starter.
For this line of generators is possible the supply of a differential protection circuit, in addition is possible the supply of trolleys for the handling of the unit.
The Stage V engine allows the use of the generator set also for mobile use, for example for road construction sites and rental services. The generator is suitable for applications in different contexts such as: hospitals, industries, shopping centers, hotels, airports, banks, universities, stadiums, offices, etc..
Genmac 11,8KVA generators are highly reliable machines, built with quality components to be used in professional field, where reliability is fundamental.
Genmac Urban generators are supplied with AVR card, tank with collection tank and central lifting hook as standard on all models.
AVR Voltage Regulator
The AVR is essential to make the generator work at its best, in fact it all needs an electronic control system, an AVR in fact, which ensures the proper functioning of the machine and the electrical network behind it.
The purpose of the AVR, in a current generator, is to keep the output stable. And if its operation is very simple when resistive loads are fed, more complex is the matter in case of mainly inductive loads: the delayed phase shift current counteracts the inductor magnetic field, causing a voltage drop at the alternator terminals; to compensate for this phenomenon, the AVR intervenes automatically by increasing the excitation current, until the returns to the nominal value. If the load is capacitive, the current acts as a magnetizer for the inductor causing an increase in voltage exit, and the AVR intervenes by reducing the excitation current.
TECHNICAL CHARACTERISTICS OF GENERATOR GENMAC Urban G11600KS-M5 11,8KVA
Phase Type: SinglePhase/ThreePhase
SinglePhase Continuous Power: 3.5KVA / 2.8KW
SinglePhase Maximum Power: 4KVA / 3.2KW
ThreePhase Continuous Power: 10.6KVA / 8.5KW
ThreePhase Maximum Power: 11.8KVA / 9.4KW
Motor: Kohler KDW702
Emissions Standard: Stage V
Starting: Electric
Power Supply: Diesel
Receptacle Panel: 1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 16A 400V - 1 x 32A 400V
Voltage: 230 / 400 V
Frequency: 50 Hz
Motor RPM: 3000 rpm
Tank Capacity: 50 l
Autonomy @ 75%: 17 h fixed rpm
Voltage regulator : AVR
Sound pressure @7m: 68 dBa
Length (mm): 1475
Width (mm): 710
Height (mm): 1060
Dry weight (Kg): 400
If you are looking for another product then you can consult other terrestrial generators in our catalog.
Images and technical data are not binding.
Integer eget turpis non ipsum tempor pellentesque quis eget erat. Duis ipsum leo, pulvinar nec eros hendrerit, consequat tincidunt augue. Proin et est at velit lobortis varius sed sed lectus. Vivamus vitae neque nibh. Proin et lectus dolor. Donec a velit ipsum. Morbi vel nisi cursus, cursus urna a, ornare ex. Mauris vitae feugiat diam. Praesent scelerisque ex faucibus nisl pulvinar vulputate. Maecenas et molestie neque. Morbi sed metus egestas, pharetra sapien eu, efficitur felis. Phasellus facilisis ex id lorem rhoncus efficitur. Aenean varius nec lacus
GENMAC AUTOMATIC TRANSFER SWITCH ATS-L4520 2P 50Hz 1PH 230V 40A
Earth fault breaker Urban single phase
- Phase
- Single phase / Three phase
- Maximum power single phase (KW)
- 3.2
- Continuous power single phase (KW)
- 2.8
- Maximum power single phase (KVA)
- 4
- Continuous power single phase (KVA)
- 3.5
- Maximum power three phase (KW)
- 9.4
- Continuous power three phase (KW)
- 8.5
- Maximum power three phase (KVA)
- 11.8
- Continuous power three phase (KVA)
- 10.6
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Sockets configuration
- 1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 16A 400V - 1 x 32A 400V
- Engine
- Kohler KDW702
- Emissions Regulations
- Stage 5
- Engine rpm (rpm)
- 3000
- Starting system
- Electric
- Cooling
- Water
- Poles
- 2
- Fuel tank capacity (L)
- 50
- Running time (h)
- 17
- Acoustic pressure
- 68 dB(A) at 7 m
- Length (mm)
- 1475
- Width (mm)
- 710
- Height (mm)
- 1060
- Dry weight (Kg)
- 400
- Silenced
- Yes
- Super silenced
- Yes
- ATS Switch device
- Optional
- Voltage regulator
- AVR
- Engine manufacturer
- Kohler