<iframe src="https://www.googletagmanager.com/ns.html?id=GTM-PHW6DPD" height="0" width="0" style="display:none;visibility:hidden">

GENMAC Urban G15000KS-M5 GENERATOR 14,9KVA

GENMAC Urban G15000KS Diesel Generating set 15 KVA 12 KW Silenced
search
  • GENMAC Urban G15000KS Diesel Generating set 15 KVA 12 KW Silenced
GENMAC
Urban G15000KS-M5
New product

Phase Type: Single-Phase / Three-Phase
Single-Phase Continuous Power: 4.5KVA / 3.6KW
Single-Phase Maximum Power: 5.0KVA / 4.0KW
Three-Phase Continuous Power: 13.5KVA / 10.8KW
Three-Phase Maximum Power: 14.9KVA / 11.9KW
Motor: Kohler KDW1003
Emissions Standard: Stage V
Starting: Electric
Power Supply: Diesel
Receptacle Panel: 1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 16A 400V - 1 x 32A 400V
Voltage: 230 / 400 V
Frequency: 50 Hz
Motor RPM: 3000 rpm
Tank Capacity: 50 l
Autonomy @ 75%: 14 h fixed rpm
Voltage regulator : AVR
Sound pressure @7m: 68 dBa
Length (mm): 1475
Width (mm): 710
Height (mm): 1060
Dry weight (Kg): 417

Technical features
Phase
Single phase / Three phase
Maximum power single phase (KW)
4
Continuous power single phase (KW)
3.6
Maximum power single phase (KVA)
5
Continuous power single phase (KVA)
4.2
Maximum power three phase (KW)
11.9
Continuous power three phase (KW)
10.8
Maximum power three phase (KVA)
14.9
Continuous power three phase (KVA)
13.5
Fuel
Diesel
Frequency (Hz)
50
Voltage (V)
230 / 400
Sockets configuration
1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 16A 400V - 1 x 32A 400V
Engine
Kohler KDW1003
Emissions Regulations
Stage 5
Engine rpm (rpm)
3000
Starting system
Electric
Cooling
Water
Poles
2
Fuel tank capacity (L)
50
Running time (h)
14
Acoustic pressure
68 dB(A) at 7 m
Length (mm)
1475
Width (mm)
710
Height (mm)
1060
Dry weight (Kg)
417
Silenced
Yes
Super silenced
Yes
ATS Switch device
Optional
Voltage regulator
AVR
Engine manufacturer
Kohler
Details

GENMAC URBAN G15000KS-M5 SINGLE-PHASE / THREE-PHASE GENERATOR 14,9KVA

The generator GENMAC Urban G15000KS-M5 single-phase / three-phase is equipped with a Kohler KDW1003 Stage V diesel-powered engine capable of delivering a power of 14,9KVA with AVR voltage regulator.

The high quality professional silenced diesel generator of the construction series, Genmac Urban with power of 14,9KVA, produced by Italian company Genmac. The generator is equipped with an oversized engine with water cooling and a practical electric starter.

For this line of generators is possible the supply of a differential protection circuit, in addition is possible the supply of trolleys for the handling of the unit.

The Stage V engine allows the use of the generator set also for mobile use, for example for road construction sites and rental services. The generator is suitable for applications in different contexts such as: hospitals, industries, shopping centers, hotels, airports, banks, universities, stadiums, offices, etc..

Genmac 14,9KVA generators are highly reliable machines, built with quality components to be used in professional field, where reliability is fundamental.

Genmac Urban generators are supplied with AVR card, tank with collection tank and central lifting hook as standard on all models.

AVR Voltage Regulator

The AVR is essential to make the generator work at its best, in fact it all needs an electronic control system, an AVR in fact, which ensures the proper functioning of the machine and the electrical network behind it.

The purpose of the AVR, in a current generator, is to keep the output stable. And if its operation is very simple when resistive loads are fed, more complex is the matter in case of mainly inductive loads: the delayed phase shift current counteracts the inductor magnetic field, causing a voltage drop at the alternator terminals; to compensate for this phenomenon, the AVR intervenes automatically by increasing the excitation current, until the returns to the nominal value. If the load is capacitive, the current acts as a magnetizer for the inductor causing an increase in voltage exit, and the AVR intervenes by reducing the excitation current.

TECHNICAL CHARACTERISTICS OF GENERATOR GENMAC Urban G15000KS-M5 14,9KVA

Phase Type: SinglePhase / ThreePhase
SinglePhase Continuous Power: 4.5KVA / 3.6KW
SinglePhase Maximum Power: 5.0KVA / 4.0KW
ThreePhase Continuous Power: 13.5KVA / 10.8KW
ThreePhase Maximum Power: 14.9KVA / 11.9KW
Motor: Kohler KDW1003
Emissions Standard: Stage V
Starting: Electric
Power Supply: Diesel
Receptacle Panel: 1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 16A 400V - 1 x 32A 400V
Voltage: 230 / 400 V
Frequency: 50 Hz
Motor RPM: 3000 rpm
Tank Capacity: 50 l
Autonomy @ 75%: 14 h fixed rpm
Voltage regulator : AVR
Sound pressure @7m: 68 dBa
Length (mm): 1475
Width (mm): 710
Height (mm): 1060
Dry weight (Kg): 417

If you are looking for another product then you can consult other terrestrial generators in our catalog.

Images and technical data are not binding.

Suspendisse a porta dui. Sed sit amet vehicula turpis, a vulputate lacus. Morbi varius mi arcu, ac rhoncus ex laoreet gravida. Vestibulum blandit metus eu nulla ornare efficitur. Duis molestie ipsum orci, eu aliquam nisi lacinia at. Maecenas mattis porttitor urna, vitae mollis lacus dapibus in. Sed aliquet convallis urna eget vulputate. Nullam malesuada, metus sed laoreet ultrices, justo nulla dapibus ante, nec maximus nisl sapien at dolor. Proin sed augue accumsan leo congue pellentesque. Quisque nec vestibulum mauris. Nullam ligula arcu,

Technical Sheet / Manuals
Related Accessories
List price
15.756,30 € tax incl.
12.915,00 € tax excl.
Discounted Price
7.995,88 € tax incl.
6.554,00 € tax excl.
Quantity

loader
135,00 € shipped to Italy

Calculate Shipping Cost
Add to wishlist
Download PDF
Ask a question
Product: GENMAC Urban G15000KS-M5 GENERATOR 14,9KVA
Offer on letterhead
Product: GENMAC Urban G15000KS-M5 GENERATOR 14,9KVA
Technical features
Phase
Single phase / Three phase
Maximum power single phase (KW)
4
Continuous power single phase (KW)
3.6
Maximum power single phase (KVA)
5
Continuous power single phase (KVA)
4.2
Maximum power three phase (KW)
11.9
Continuous power three phase (KW)
10.8
Maximum power three phase (KVA)
14.9
Continuous power three phase (KVA)
13.5
Fuel
Diesel
Frequency (Hz)
50
Voltage (V)
230 / 400
Sockets configuration
1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 16A 400V - 1 x 32A 400V
Engine
Kohler KDW1003
Emissions Regulations
Stage 5
Engine rpm (rpm)
3000
Starting system
Electric
Cooling
Water
Poles
2
Fuel tank capacity (L)
50
Running time (h)
14
Acoustic pressure
68 dB(A) at 7 m
Length (mm)
1475
Width (mm)
710
Height (mm)
1060
Dry weight (Kg)
417
Silenced
Yes
Super silenced
Yes
ATS Switch device
Optional
Voltage regulator
AVR
Engine manufacturer
Kohler
Details
Technical Sheet / Manuals
Related Accessories