<iframe src="https://www.googletagmanager.com/ns.html?id=GTM-PHW6DPD" height="0" width="0" style="display:none;visibility:hidden">

GENMAC Urban-Rent RG9600KS-M5 GENERATOR 10,4KVA

GENMAC Urban G15000KS Diesel Generating set 15 KVA 12 KW Silenced
search
  • GENMAC Urban G15000KS Diesel Generating set 15 KVA 12 KW Silenced
GENMAC
Urban-Rent RG9600KS-M5
New product

OUT OF PRODUCTION

Phase Type: Single Phase
Continuous Power: 9.4KVA / 8.5KW
Maximum Power: 10.4KVA / 9.4KW
Engine: Kohler KDW702
Emissions Standard: Stage V
Starting: Electric
Power Supply: Diesel
Receptacle Panel: 1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 32A 230V - 1 x 63A 230V
Voltage: 230 V
Frequency: 50 Hz
Motor RPM: 3000 rpm
Tank Capacity: 50 l
Autonomy @ 75%: 17 h fixed rpm
Voltage regulator: AVR
Sound pressure @7m: 67 dBa
Length (mm): 1475
Width (mm): 710
Height (mm): 1060
Dry weight (Kg): 400

Technical features
Phase
Single phase
Maximum power single phase (KW)
9.4
Continuous power single phase (KW)
8.5
Maximum power single phase (KVA)
10.4
Continuous power single phase (KVA)
9.4
Fuel
Diesel
Frequency (Hz)
50
Voltage (V)
230
Sockets configuration
1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 32A 230V - 1 x 63A 230V
Engine
Kohler KDW702
Emissions Regulations
Stage 5
Engine rpm (rpm)
3000
Starting system
Electric
Cooling
Water
Poles
2
Fuel tank capacity (L)
50
Running time (h)
17
Acoustic pressure
67 dB(A) at 7 m
Length (mm)
1475
Width (mm)
710
Height (mm)
1060
Dry weight (Kg)
400
Silenced
Yes
Super silenced
Yes
ATS Switch device
Optional
Voltage regulator
AVR
Engine manufacturer
Kohler
Details

GENMAC Urban-Rent RG9600KS-M5 SINGLE-PHASE GENERATOR 10,4KVA

The generator GENMAC Urban-Rent RG9600KS-M5 single-phase is equipped with a diesel-powered Kohler engine capable of delivering 10,4KVA with AVR voltage regulator.

The high quality professional silenced diesel generator of the construction series, Genmac Urban-Rent with power of 10,4KVA, produced by Italian company Genmac. The generator is equipped with an oversized engine with water cooling and a practical electric starter.

For this line of generators is possible the supply of a differential protection circuit, in addition is possible the supply of trolleys for the handling of the unit.

The Genmac Urban-Rent silenced generator specific for mobile and rental applications. Easy to use and move. It mounts the latest generation engine with low emission level, for an energy that respects the environment.

Genmac 10,4KVA generators are highly reliable machines, built with quality components to be used in the professional field, where reliability is fundamental.

Genmac generators are supplied with AVR card, tank with collection tank and central lifting hook as standard on all models.

Control Panel

The control panel is composed as follows:
No. 1 CEE 63A 230V
No. 1 CEE 32A 230V
No. 2 CEE 16A 230V
No. 1 Schuko 16A 230V
Thermal circuit breaker
Circuit breaker
- Generator power monitoring (kW, kV Ar, kV A & pf)
- Fuel level meter
- Overload protection (kW & kV Ar)
- Low oil pressure protection
- High coolant temperature protection
- Low fuel level protection
- Charger alternator failure
- RPM protection
- Oil pressure and engine temperature readout
Analogue fuel level gauge
Emergency stop button
Quick connector for remote start/ATS
On/off switch

AVR Voltage Regulator

The AVR is indispensable to make the generator work at its best, in fact it all needs an electronic control system, an AVR in fact, which ensures the proper functioning of the machine and the electrical network behind it.

The purpose of the AVR, in a current generator, is to keep the output stable. And if its operation is very simple when resistive loads are fed, more complex is the matter in case of mainly inductive loads: the delayed phase shift current counteracts the inductor magnetic field, causing a voltage drop at the alternator output terminals; to compensate for this phenomenon, the AVR intervenes automatically by increasing the excitation current, until the output returns to the nominal value. If the load is capacitive, the current acts as a magnetizer for the inductor causing an increase in the output voltage, and the AVR intervenes by reducing the excitation current.

TECHNICAL CHARACTERISTICS OF GENERATOR GENMAC Urban-Rent RG9600KS-M5 10,4KVA

Phase Type: Single Phase
Continuous Power: 9.4KVA / 8.5KW
Maximum Power: 10.4KVA / 9.4KW
Engine: Kohler KDW702
Emissions Standard: Stage V
Starting: Electric
Power Supply: Diesel
Receptacle Panel: 1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 32A 230V - 1 x 63A 230V
Voltage: 230 V
Frequency: 50 Hz
Motor RPM: 3000 rpm
Tank Capacity: 50 l
Autonomy @ 75%: 17 h fixed rpm
Voltage regulator: AVR
Sound pressure @7m: 67 dBa
Length (mm): 1475
Width (mm): 710
Height (mm): 1060
Dry weight (Kg): 400

If you are looking for another product then you can consult other terrestrial generators in our catalog.

Images and technical data are not binding.

Technical Sheet / Manuals
Related Accessories
Ask for availability
Add to wishlist
Download PDF
Ask a question
Product: GENMAC Urban-Rent RG9600KS-M5 GENERATOR 10,4KVA
Offer on letterhead
Product: GENMAC Urban-Rent RG9600KS-M5 GENERATOR 10,4KVA
Technical features
Phase
Single phase
Maximum power single phase (KW)
9.4
Continuous power single phase (KW)
8.5
Maximum power single phase (KVA)
10.4
Continuous power single phase (KVA)
9.4
Fuel
Diesel
Frequency (Hz)
50
Voltage (V)
230
Sockets configuration
1 x Schuko 16A 230V - 2 x 16A 230V - 1 x 32A 230V - 1 x 63A 230V
Engine
Kohler KDW702
Emissions Regulations
Stage 5
Engine rpm (rpm)
3000
Starting system
Electric
Cooling
Water
Poles
2
Fuel tank capacity (L)
50
Running time (h)
17
Acoustic pressure
67 dB(A) at 7 m
Length (mm)
1475
Width (mm)
710
Height (mm)
1060
Dry weight (Kg)
400
Silenced
Yes
Super silenced
Yes
ATS Switch device
Optional
Voltage regulator
AVR
Engine manufacturer
Kohler
Details
Technical Sheet / Manuals