MOSA GE 14000 KD-GS

MOSA GE 14000 LD/GS EAS
search
  • MOSA GE 14000 LD/GS EAS
MOSA
CD6A5010 /
New product

OUT OF STOCK

Single-phase continuous use power: 4 KW
Three phase maximum power: 12 KW
Three phase continuous use power: 10.8 KW
Fuel: Diesel
Voltage: 230 V / 400 V
Frequency: 50 Hz
Engine: KOHLER KD 477/2
Starting: Electric
Acoustic power measured LwA: 105 dB(A) (80 dB(A) @ 7 m)
Consumption: 2.8 Lt/h at 75% of the load
Length: 1000 mm
Width: 610 mm
Height: 750 mm
Weight: 191 Kg
Compound

Technical features
Phase
Single phase / Three phase
Continuous power single phase (KW)
4
Continuous power single phase (KVA)
5
Maximum power three phase (KW)
12
Continuous power three phase (KW)
10.8
Maximum power three phase (KVA)
15
Continuous power three phase (KVA)
13.5
Fuel
Diesel
Frequency (Hz)
50
Voltage (V)
230 / 400
Sockets configuration
1 x 400V 32A 3P+N+T CEE - 1 x 230V 32A 2P+T CEE - 1 x 230V 16A 2P+T SCHUKO
Engine
Kohler KD 477/2, 4 stroke
Emissions Regulations
Stationary Use
Engine rpm (rpm)
3000
Starting system
Electric
Engine capacity (cm³)
954
Number cylinders
2
Cooling
Air
Inyección
Direct
Alternator
Sincrono trifase, autoeccitato, autoregolato
Fuel tank capacity (L)
18
Consumption (L/h)
2.8 at 75% of the load
Running time (h)
6.5 at 75% of the load
Acoustic power
105 dB(A)
Acoustic pressure
80 dB(A) at 7 m
Length (mm)
1000
Width (mm)
610
Height (mm)
750
Dry weight (Kg)
191
Silenced
No
Super silenced
No
Product type
Generator
ATS Switch device
Optional
Voltage regulator
Compound
Engine manufacturer
Kohler
Details

MOSA GE14000 KD-GS 12 KW ELECTROGEN GROUP

MOSA GE14000 KD-GS three-phase 12 KW generator set with Kohler diesel engine. The MOSA GE14000 KD-GS generator set is equipped with electric start. The alternator of the MOSA GE14000 KD-GS generator set is synchronous, three-phase, self-excited, self-regulated, brushless and class H insulated.

MOSA is compact and convenient easily transportable thanks to the reduced dimensions due to an essential equipment, are indicated to all those who need an economic source of energy, however, assembled with a first-rate components that guarantees the absolute reliability. The recessed front protects the sockets, controls and instruments from accidental damage while the steel stretcher provides protection for the entire machine.
The MOSA GE14000 KD-GS generator set is suitable for a wide range of uses such as construction, equipment rental, events.

Oil Alert
The ''Oil Alert'' system is designed to prevent engine damage caused by an insufficient amount of oil in the sump. This system automatically shuts down the engine before the oil level falls below the safety limit.

Technical Specifications:

Three-phase stand-by output: 15 kVA (12 kW) / 400 V / 21.7 A
Three-phase PRP output: 13.5 kVA (10.8 kW) / 400 V / 19.5 A
Single-phase PRP output: 5 kVA / 230 V / 21.7 A
Cos ϕ: 0.8
Insulation class: H

ENGINE TECHNICAL DATA
Model: KOHLER KD 477/2
Net stand-by power: 14.9 kW (20.3 HP)
Net PRP power: 13.5 kW (18.4 HP)
Cylinders / Displacement: 2/ 954 cm3
Regime: 3000 rpm
Fuel consumption 2.8 l/h

GOVERNMENTAL SPECIFICATIONS
Tank capacity: 18 l
Run time (75% of PRP): 6.5 h
Protection class: IP 23
Measured acoustic power LwA: 105 dB(A) (80 dB(A) @ 7 m)
Length: 1000 mm
Width: 610 mm
Height: 750 mm
Weight: 191 Kg

Features:
- Electric start
- Engine stop for low oil level and engine temperature
- Recessed front panel to protect sockets
- Circuit breaker
- Differential circuit breaker
-. Prepared for use with automatic panel EAS
- Conforms to CE directives

If you are looking for another product such as Generator Set MOSA GE14000 KD-GS then you can see on our catalog other terrestrial gensets.

Pictures and technical data are not binding.

Related Accessories
Ask for availability
Add to wishlist
Download PDF
Ask a question
Product: MOSA GE 14000 KD-GS
Offer on letterhead
Product: MOSA GE 14000 KD-GS
Technical features
Phase
Single phase / Three phase
Continuous power single phase (KW)
4
Continuous power single phase (KVA)
5
Maximum power three phase (KW)
12
Continuous power three phase (KW)
10.8
Maximum power three phase (KVA)
15
Continuous power three phase (KVA)
13.5
Fuel
Diesel
Frequency (Hz)
50
Voltage (V)
230 / 400
Sockets configuration
1 x 400V 32A 3P+N+T CEE - 1 x 230V 32A 2P+T CEE - 1 x 230V 16A 2P+T SCHUKO
Engine
Kohler KD 477/2, 4 stroke
Emissions Regulations
Stationary Use
Engine rpm (rpm)
3000
Starting system
Electric
Engine capacity (cm³)
954
Number cylinders
2
Cooling
Air
Inyección
Direct
Alternator
Sincrono trifase, autoeccitato, autoregolato
Fuel tank capacity (L)
18
Consumption (L/h)
2.8 at 75% of the load
Running time (h)
6.5 at 75% of the load
Acoustic power
105 dB(A)
Acoustic pressure
80 dB(A) at 7 m
Length (mm)
1000
Width (mm)
610
Height (mm)
750
Dry weight (Kg)
191
Silenced
No
Super silenced
No
Product type
Generator
ATS Switch device
Optional
Voltage regulator
Compound
Engine manufacturer
Kohler
Details
Related Accessories