GENERATOR FISCHER PANDA AGT-DC 11000-48V PMS
Phase type: Single phase
Maximum power Single-phase: 11 KW
Single phase continuous power: 10.9 KW
Frequency: 50 Hz
Voltage: 48 V
Inverter
Motor RPM: 2300-2900 rpm
Displacement: 898
Cooling: Water
Acoustic pressure: 53 dB(A) at 7 m
Length: 660 mm
Width: 580 mm
Height: 616 mm
Dry weight: 170 Kg
- Phase
- Single phase
- Maximum power single phase (KW)
- 11
- Continuous power single phase (KW)
- 10.9
- Maximum power single phase (KVA)
- 11
- Continuous power single phase (KVA)
- 10.9
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 48
- Engine
- Kubota D902
- Engine rpm (rpm)
- 2300 - 2900
- Speed governor
- Electronic
- Engine capacity (cm³)
- 898
- Number cylinders
- 3
- Oil capacity (L)
- 3.7
- Cooling
- Water
- Poles
- 2
- Bore x stroke (mm)
- 72x73.6
- Motor insulation class
- H
- Length (mm)
- 660
- Width (mm)
- 580
- Height (mm)
- 616
- Dry weight (Kg)
- 170
- Silenced
- Yes
- Super silenced
- Yes
- Product type
- Generator
- Voltage regulator
- Inverter
- Engine manufacturer
- Kubota
MARINE GENERATOR FISCHER PANDA AGT-DC11000 48V SUPERSILENCED 10.9 KW
Generator for boats Fischer Panda AGT-DC11000 48V single-phase 10.9 KW, also called marine generator, with variable speed motor from 2300 rpm to 2900 rpm. The Fischer Panda AGT-DC11000 48V marine generator is designed with a soundproof cabin that makes it super-silent. The Fischer Panda AGT-DC11000 48V marine generator is built with a Kubota diesel-powered engine. The Fischer Panda AGT-DC11000 48V marine generator alternator is 2-pole and has H insulation class. With its compact size and low weight, the Fischer Panda AGT-DC11000 48V marine generator is also suitable for installation on small boats.
Ideal for systems where the generator operates for short intervals to charge the power bank and support peak power periods.
In this version, the charging voltage is controlled by an integrated AGT controller that regulates engine revs.
The engine revs can therefore be variable to achieve the required performance. However, when installing this version, the batteries must be positioned close to the generator.
- Designed for DC-AC power systems with battery plus inverter
- The generator is required to operate intermittently only
- Optimum use of the generator
- High degree of efficiency
- Compact design
- Reduced fuel consumption
Hybrid AC energy - indirect AC
Battery charging generators produce direct current and generally function as part of a hybrid power supply system. Battery levels are monitored and charged automatically by the generator. An inverter supplies power to the on-board 230 V consumers. These systems are ideal for typically variable power requirements that do not require a generator to operate constantly during the day.
If you are looking for a marine generator set like the Fischer Panda AGT-DC11000 48V then you can browse the entire catalogue of marine generators.
Images and technical data are not binding.
- Phase
- Single phase
- Maximum power single phase (KW)
- 11
- Continuous power single phase (KW)
- 10.9
- Maximum power single phase (KVA)
- 11
- Continuous power single phase (KVA)
- 10.9
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 48
- Engine
- Kubota D902
- Engine rpm (rpm)
- 2300 - 2900
- Speed governor
- Electronic
- Engine capacity (cm³)
- 898
- Number cylinders
- 3
- Oil capacity (L)
- 3.7
- Cooling
- Water
- Poles
- 2
- Bore x stroke (mm)
- 72x73.6
- Motor insulation class
- H
- Length (mm)
- 660
- Width (mm)
- 580
- Height (mm)
- 616
- Dry weight (Kg)
- 170
- Silenced
- Yes
- Super silenced
- Yes
- Product type
- Generator
- Voltage regulator
- Inverter
- Engine manufacturer
- Kubota