GENERATOR FISCHER PANDA AGT-DC 8000-24V
Phase Type: Single-phase
Maximum Output: 8000 W
Continuous Output: 6400 W
Maximum Output: 8 kVA
Continuous Output: 6.4 kVA
Frequency: 50 Hz
Voltage: 24 V
Inverter
Engine rpm: 2200-2600 rpm
Dispacement: 719 cc.
Cooling: Water
Sound pressure: 53 dB(A) at 7 m
Length: 660 mm
Width: 515 mm
Height: 594 mm
Dry weight: 160 Kg
- Phase
- Single phase
- Maximum power single phase (KW)
- 8
- Continuous power single phase (KW)
- 6.4
- Maximum power single phase (KVA)
- 8
- Continuous power single phase (KVA)
- 6.4
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 24
- Engine
- Kubota D722
- Engine rpm (rpm)
- 2200 - 2600
- Speed governor
- Electronic
- Engine capacity (cm³)
- 719
- Number cylinders
- 3
- Oil capacity (L)
- 3.8
- Cooling
- Water
- Poles
- 2
- Bore x stroke (mm)
- 67 x 68
- Motor insulation class
- H
- Length (mm)
- 660
- Width (mm)
- 515
- Height (mm)
- 594
- Dry weight (Kg)
- 160
- Silenced
- Yes
- Super silenced
- Yes
- Product type
- Generator
- Voltage regulator
- Inverter
- Engine manufacturer
- Kubota
MARINE GENERATOR FISCHER PANDA AGT-DC8000 24V SUPERSILENCED 6.4 KW
Generator for boats Fischer Panda AGT-DC8000 24V single-phase 6,4 KW, also called marine generator, with variable speed motor from 2200 rpm to 2600 rpm. The Fischer Panda AGT-DC8000 24V marine generator is designed with a soundproof cabin that makes it super-silent. The Fischer Panda AGT-DC8000 24V marine generator is built with a Kubota diesel-powered engine. The Fischer Panda AGT-DC8000 24V marine generator alternator is 2-pole and has H insulation class. With its compact size and low weight, the Fischer Panda AGT-DC8000 24V marine generator is also suitable for installation on small boats.
Hybrid AC energy - indirect AC
Battery charging generators produce direct current and generally function as part of a hybrid power supply system. Battery levels are monitored and charged automatically by the generator. An inverter supplies power to the on-board 230 V consumers. These systems are ideal for typically variable power requirements that do not require a generator to operate constantly during the day.
Ideal for systems where the generator runs for short intervals to charge the power bank and support peak power periods.
In this version, the charging voltage is controlled by an integrated AGT controller that regulates engine revs.
The engine revs can therefore be variable to achieve the required performance. However, when installing this version, the batteries must be positioned close to the generator.
- Designed for DC-AC power systems with battery plus inverter
- The generator is required to operate intermittently only
- Optimum use of the generator
- High degree of efficiency
- Compact design
- Reduced fuel consumption
If you are looking for a marine generator set like the Fischer Panda AGT-DC8000 24V then you can browse the entire catalogue of marine generators.
Images and technical data are not binding.
FISCHER PANDA Service Kit Plus 7 - Maintenance Kit
- Phase
- Single phase
- Maximum power single phase (KW)
- 8
- Continuous power single phase (KW)
- 6.4
- Maximum power single phase (KVA)
- 8
- Continuous power single phase (KVA)
- 6.4
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 24
- Engine
- Kubota D722
- Engine rpm (rpm)
- 2200 - 2600
- Speed governor
- Electronic
- Engine capacity (cm³)
- 719
- Number cylinders
- 3
- Oil capacity (L)
- 3.8
- Cooling
- Water
- Poles
- 2
- Bore x stroke (mm)
- 67 x 68
- Motor insulation class
- H
- Length (mm)
- 660
- Width (mm)
- 515
- Height (mm)
- 594
- Dry weight (Kg)
- 160
- Silenced
- Yes
- Super silenced
- Yes
- Product type
- Generator
- Voltage regulator
- Inverter
- Engine manufacturer
- Kubota