Phase Type: Single-phase / Three-phase
Maximum power LTP: 198 KVA
Maximum power LTP: 158 KW
Continuous power PRP: 180 KVA
Continuous power PRP: 144 KW
Fuel: Diesel
Frequency: 50 Hz
Voltage: 230 / 400 V
Engine: Perkins 1106D-E70TAG4
Engine rpm: 1500 rpm
Cooling: Water
Length: 3600 mm
Width: 1226 mm
Height: 2000 mm
Weight: 2200 Kg
Super silenced
AVR
- Phase
- Single phase / Three phase
- Maximum power three phase (KW)
- 132
- Continuous power three phase (KW)
- 144
- Maximum power three phase (KVA)
- 198
- Continuous power three phase (KVA)
- 180
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Engine
- Perkins 1106A-70TAG3
- Emissions Regulations
- Stage 3A
- Engine rpm (rpm)
- 1500
- Speed governor
- Electronic
- Engine capacity (cm³)
- 7010
- Number cylinders
- 6
- Oil capacity (L)
- 17.2
- Cooling
- Water
- Alternator
- Synchronous, self-excited
- Width (mm)
- 1056
- Height (mm)
- 2000
- Dry weight (Kg)
- 2200
- AVR
- Yes
- Silenced
- Yes
- Super silenced
- Yes
- Product type
- Generator
- ATS Switch device
- No
- Voltage regulator
- AVR
- Engine manufacturer
- Perkins
GENMAC ROYAL G180PS-E3
The GENMAC ROYAL G180PS-E3 is a 180 KVA super-silenced single-phase/three-phase diesel generator with Stamford alternator and AVR voltage regulator.
Thanks to its diesel fuel supply, the GENMAC ROYAL G180PS-E3 can only consume 4.34 m³/h at full load and has a low environmental impact, making it one of the best in its class.
The long life and reliability of the GENMAC ROYAL G180PS-E3 is due to a special control procedure during the various stages of production.
The GENMAC ROYAL G180PS-E3 is suitable for applications in different contexts such as: hospitals, industries, shopping malls, hotels, airports, banks, universities, stadiums, offices, etc.
The Stage 3A engine allows the use of the generator set also for mobile use, for example for roadworks and rental services.
Control panel features
QT2A-4520
Self-standing tower with IP65 metal box Circuit breaker AMF controller DSE4520 - Voltmeter, Frequencymeter, Ammeter - Generator power (kW, kV Ar, kV A & pf) monitoring - Hour meter - Fuel level meter - Overload (kW & kV Ar) protection - Low oil pressure protection - High coolant temperature protection - Low fuel level protection - Battery charger alternator fault - Rpm protection Emergency stop button Audible alarm Terminal board for ATS connection Can Bus reading Port (if standard on the engine) Battery charger On/off switchImages and technical data are not binding.
- Phase
- Single phase / Three phase
- Maximum power three phase (KW)
- 132
- Continuous power three phase (KW)
- 144
- Maximum power three phase (KVA)
- 198
- Continuous power three phase (KVA)
- 180
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Engine
- Perkins 1106A-70TAG3
- Emissions Regulations
- Stage 3A
- Engine rpm (rpm)
- 1500
- Speed governor
- Electronic
- Engine capacity (cm³)
- 7010
- Number cylinders
- 6
- Oil capacity (L)
- 17.2
- Cooling
- Water
- Alternator
- Synchronous, self-excited
- Width (mm)
- 1056
- Height (mm)
- 2000
- Dry weight (Kg)
- 2200
- AVR
- Yes
- Silenced
- Yes
- Super silenced
- Yes
- Product type
- Generator
- ATS Switch device
- No
- Voltage regulator
- AVR
- Engine manufacturer
- Perkins