GENMAC STRONG G30JS-E3 THREE-PHASE 30 KVA DIESEL - MOTOR JOHN-DEERE STAGE 3A
Phase Type: Single-phase / Three-phase
Maximum power LTP: 33 KVA
Maximum power LTP: 26 KW
Continuous power PRP: 30 KVA
Continuous power PRP: 24 KW
Fuel: Diesel
Frequency: 50 Hz
Voltage: 230 / 400 V
Engine: John-Deere 3029TFU80
Engine rpm: 1500 rpm
Cooling: Water
Length: 2213 mm
Width: 960 mm
Height: 1258 mm
Weight: 1080 Kg
Super silenced
AVR
- Phase
- Single phase / Three phase
- Maximum power three phase (KW)
- 26
- Continuous power three phase (KW)
- 24
- Maximum power three phase (KVA)
- 33
- Continuous power three phase (KVA)
- 30
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Emissions Regulations
- Stage 3A
- Engine rpm (rpm)
- 1500
- Speed governor
- Mechanical
- Engine capacity (cm³)
- 2900
- Number cylinders
- 3
- Oil capacity (L)
- 8
- Cooling
- Water
- Alternator
- Mecc Alte
- Length (mm)
- 2213
- Width (mm)
- 960
- Height (mm)
- 1258
- Dry weight (Kg)
- 1080
- AVR
- Yes
- Silenced
- Yes
- Super silenced
- Yes
- Product type
- Generator
- ATS Switch device
- No
- Voltage regulator
- AVR
- Engine manufacturer
- John Deere
GENMAC STRONG G30JS-E3
The GENMAC STRONG G30JS-E3 is a 30 KVA super-silenced single-phase/three-phase diesel generator with Mecc Alte alternator and AVR voltage regulator.
Thanks to its diesel fuel supply, the GENMAC STRONG G30JS-E3 can only consume 0.81 m³/h at full load and has a low environmental impact, making it one of the best in its class.
The long life and reliability of the GENMAC STRONG G30JS-E3 is due to a special control procedure during the various stages of production.
The GENMAC STRONG G30JS-E3 is suitable for applications in different contexts such as: hospitals, industries, shopping malls, hotels, airports, banks, universities, stadiums, offices, etc.
The Stage 3A engine allows the use of the generator set also for mobile use, for example for roadworks and rental services.
Control panel features
QFIA-4520
Protection cover Circuit breaker AMF controller DSE4520 - Voltmeter, Frequencymeter, Ammeter - Generator power (kW, kV Ar, kV A & pf) monitoring - Hour meter - Fuel level meter - Overload (kW & kV Ar) protection - Low oil pressure protection - High coolant temperature protection - Low fuel level protection - Battery charger alternator fault - Rpm protection Emergency stop button Terminal board for ATS connection Battery charger On/off switchImages and technical data are not binding.
- Phase
- Single phase / Three phase
- Maximum power three phase (KW)
- 26
- Continuous power three phase (KW)
- 24
- Maximum power three phase (KVA)
- 33
- Continuous power three phase (KVA)
- 30
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Emissions Regulations
- Stage 3A
- Engine rpm (rpm)
- 1500
- Speed governor
- Mechanical
- Engine capacity (cm³)
- 2900
- Number cylinders
- 3
- Oil capacity (L)
- 8
- Cooling
- Water
- Alternator
- Mecc Alte
- Length (mm)
- 2213
- Width (mm)
- 960
- Height (mm)
- 1258
- Dry weight (Kg)
- 1080
- AVR
- Yes
- Silenced
- Yes
- Super silenced
- Yes
- Product type
- Generator
- ATS Switch device
- No
- Voltage regulator
- AVR
- Engine manufacturer
- John Deere