GREEN POWER GP 17000 SM/LDE SILENT GENERATOR SINGLE-PHASE ELECTRICAL START 16,3KVA
Phase Type: Single-phase
Continuous power: 14,8 KVA / 14,8 KW
Maximum power: 16,3 KVA / 16,3 KW
Motor: KOHLER KD625-2
Engine speed: 3000 rpm
Emission regulation: NOT Emitted
Starting: Electric
Fuel: Diesel
Voltage: 230 V
Frequency: 50 Hz
Socket panel: 1 x 16A 3P 230V / 1 x 63A 3P 230V
Tank capacity: 50 l
Runtime at 75% load: 12. 5 h
Consumption at 75% load: 4 Lt/h
Acoustic pressure: 77 dB(A) @ 7 m
Length: 1200 mm
Width: 700 mm
Height: 1050 mm
Dry weight: 390 Kg
- Phase
- Single phase
- Maximum power single phase (KW)
- 16.3
- Continuous power single phase (KW)
- 14.8
- Maximum power single phase (KVA)
- 16.3
- Continuous power single phase (KVA)
- 14.8
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230
- Sockets configuration
- 1 x 16A 3P 230V / 1 x 63A 3P 230V
- Engine
- Kohler KD 625/2
- Emissions Regulations
- Stationary Use
- Engine rpm (rpm)
- 3000
- Starting system
- Electric
- Engine capacity (cm³)
- 1248
- Number cylinders
- 2
- Cooling
- Air
- Alternator
- LINZ E1C13MD/2
- Poles
- 2
- Fuel tank capacity (L)
- 50
- Consumption (L/h)
- 4 At 75 % Of Load
- Running time (h)
- 12,5 at 75% load
- Acoustic pressure
- 77 dB(A) at 7 m
- Length (mm)
- 1200
- Width (mm)
- 700
- Height (mm)
- 840
- Dry weight (Kg)
- 390
- Silenced
- Yes
- Super silenced
- Yes
- ATS Switch device
- Optional
- Voltage regulator
- Capacitor / AVR (optional)
- Engine manufacturer
- Kohler
GREEN POWER GP 17000 SM/LDE SILENT GENERATOR SINGLE-PHASE ELECTRICAL START 16,3KVA
The generator GREEN POWER GP 17000 SM/LDE single-phase, is equipped with a KOHLER KD625-2 Diesel-supplied engine, complete with capacitor voltage regulator (AVR optional).
GREEN POWER GP 17000 SM/LDE is equipped with electric start and has a low fuel consumption, in fact it consumes only 4 liters/hour at 75% of the load for an autonomy of up to 12,5 hours of operation.
The generator GREEN POWER GP 17000 SM/LDE is equipped with silenced casing that can be opened in two sections made of sheet 20/10, soundproofing material in class 1, internal muffler. Thanks to these devices, the generator can be considered super-silenced, with a noise emission of only 77 dB recorded at a distance of 7 meters from the source.
The generator guarantees efficient and silent operation thanks to the KOHLER KD625-2 engine, which allows to deliver a maximum power of 16,3KVA.
ATS AUTOMATIC STARTING FRAME
The GREEN POWER GP 17000 SM/LDE generator is designed for use with an ATS automatic start-up panel. Thanks to this, you will no longer have to worry about blackouts, in the event of a power failure this panel is able to automatically turn on the generator and allow you to continue your business.
The generator control panel consists of:
- Thermomagnetic circuit breaker and isolation control
- Sockets: 1 x 16A 3P 230V / 1 x 63A 3P 230V
- ATS arrangement
- Votmeter
- Ammeter
- Hour meter
- Ignition switch
- Emergency stop button
TECHNICAL FEATURES GREEN POWER GP 17000 SM/LDE
Phase Type: Single-phase
Continuous output: 14,8 KVA / 14,8 KW
Maximum output: 16,3 KVA / 16,3 KW
Motor: KOHLER KD625-2
Engine speed: 3000 rpm
Emission regulation: NOT Emitted
Starting: Electric
Fuel: Diesel
Voltage: 230 V
Frequency: 50 Hz
Socket panel: 1 x 16A 3P 230V / 1 x 63A 3P 230V
Tank capacity: 50 l
Runtime at 75% load: 12. 5 h
Consumption at 75% load: 4 Lt/h
Acoustic pressure: 77 dB(A) @ 7 m
Length: 1200 mm
Width: 700 mm
Height: 1050 mm
Dry weight: 390 Kg
Are you looking for a generator with different technical characteristics? Here you can find the area dedicated to GREENPOWER generators or other specialized brands.
Images and technical data not binding.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Curabitur faucibus iaculis velit. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Nam consequat sit amet nisi vitae euismod. Aenean luctus, nunc at pharetra tristique, eros dolor fermentum tellus, sit amet sodales sem felis et quam. Sed fringilla arcu magna, id maximus elit pretium at. In et tempus nulla, sed finibus magna. Nullam molestie est ornare odio luctus, quis tempus libero luctus. Nullam justo ex, scelerisque eget volutpat ut, malesuada eget mi. Mauris nec ornare massa, sed rhoncus tortor. Curabitur a sem tortor. Donec fringilla commodo lacus, sit amet feugiat nibh blandit ultricies. Nullam tristique sed augue at
copy of GREEN POWER AUTOMATIC SWITCHBOARD WITH SWITCHING IN ADDITION TO MANUAL SWITCHBOARD
copy of GREEN POWER AUTOMATIC SWITCHBOARD WITH SWITCHING IN ADDITION TO MANUAL SWITCHBOARD
GREEN POWER BUILDING SITE TROLLEY
GREEN POWER PREPARATION FOR CONNECTION TO SEPARATE AUTOMATIC PANEL
- Phase
- Single phase
- Maximum power single phase (KW)
- 16.3
- Continuous power single phase (KW)
- 14.8
- Maximum power single phase (KVA)
- 16.3
- Continuous power single phase (KVA)
- 14.8
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230
- Sockets configuration
- 1 x 16A 3P 230V / 1 x 63A 3P 230V
- Engine
- Kohler KD 625/2
- Emissions Regulations
- Stationary Use
- Engine rpm (rpm)
- 3000
- Starting system
- Electric
- Engine capacity (cm³)
- 1248
- Number cylinders
- 2
- Cooling
- Air
- Alternator
- LINZ E1C13MD/2
- Poles
- 2
- Fuel tank capacity (L)
- 50
- Consumption (L/h)
- 4 At 75 % Of Load
- Running time (h)
- 12,5 at 75% load
- Acoustic pressure
- 77 dB(A) at 7 m
- Length (mm)
- 1200
- Width (mm)
- 700
- Height (mm)
- 840
- Dry weight (Kg)
- 390
- Silenced
- Yes
- Super silenced
- Yes
- ATS Switch device
- Optional
- Voltage regulator
- Capacitor / AVR (optional)
- Engine manufacturer
- Kohler