GENERATING SET 20KW 1500 RPM WITH MANUAL CONTROL PANEL
Phase type: Single-phase / Three-phase
Maximum three-phase power: 22 KW / 27.5 KVA
Three-phase continuous power: 20 KW / 25 KVA
Maximum single-phase power: 7.33 KW / 9.17 KVA
Single-phase continuous use power: 6.67 KW / 8.33 KVA
Fuel: Diesel
Voltage: 230 V / 400 V
Frequency: 50 Hz
Motor: KOHLER KDI 2504M
Engine speed: 1500 rpm
Starting: Electric
Consumption: 4.4 Lt/h at 75% load
Length: 1700 mm
Width: 700 mm
Height: 1050 mm
Weight: 620 Kg
Super-silenced
AVR
- Phase
- Single phase / Three phase
- Maximum power single phase (KW)
- 7.33
- Continuous power single phase (KW)
- 6.67
- Maximum power single phase (KVA)
- 9.1
- Continuous power single phase (KVA)
- 8.3
- Maximum power three phase (KW)
- 22
- Continuous power three phase (KW)
- 20
- Maximum power three phase (KVA)
- 27.5
- Continuous power three phase (KVA)
- 25
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Sockets configuration
- 1 x 400V 32A 5P CEE - 1 x 230V 16A 3P CEE
- Engine
- Kohler KDI 2504 M
- Emissions Regulations
- Stage 3A
- Engine rpm (rpm)
- 1500
- Speed governor
- Mechanical
- Starting system
- Electric
- Engine capacity (cm³)
- 2482
- Number cylinders
- 4
- Cooling
- Water
- Alternator
- Brushless
- Poles
- 4
- Protection degree
- IP44
- Bore x stroke (mm)
- 88 x 102
- Fuel tank capacity (L)
- 55
- Consumption (L/h)
- 4.4
- Running time (h)
- 12.5
- Acoustic pressure
- 68 dB(A) at 7 m
- Length (mm)
- 1700
- Width (mm)
- 700
- Height (mm)
- 1050
- Dry weight (Kg)
- 620
- AVR
- Yes
- Silenced
- Yes
- Super silenced
- Yes
- Product type
- Generator
- ATS Switch device
- No
- Voltage regulator
- AVR
- Engine manufacturer
- Kohler
Single/three-phase 25KVA generator super-silenced with manual control panel
This is a single/three phase 25KVA generator with a 1500 rpm Kohler diesel engine, compact and easy to use, mounted on a fixed base. This generator is equipped with a soundproofed cabin made of structural steel plate, weatherproofing and an interior lining of soundproofing material with high noise reduction, which makes this generating set super-silenced.
This generator consists of a Stamford, Mecc Alte or Marelli Motori, self-excited, brushless alternator with AVR voltage regulator. The generator is equipped with an electric starter with a low fuel consumption battery, consuming only 4,4 litres per hour at 75% load. The fuel tank is incorporated in the crankcase for ease of use.
This generator is perfect for use outdoors, such as on construction sites.
The generator is part of the Industrial range and is characterised by its versatility for installation in urban environments such as shops or shopping centres, for the telecommunications environment, for military applications and much more.
Technical characteristics of the generator:
Phase type: Single-phase / Three-phase
Maximum three-phase power: 22 KW / 27.5 KVA
Three-phase continuous power: 20 KW / 25 KVA
Maximum single-phase power: 7.33 KW / 9.17 KVA
Single-phase continuous use power: 6.67 KW / 8.33 KVA
Fuel: Diesel
Voltage: 230 V / 400 V
Frequency: 50 Hz
Motor: KOHLER KDI 2504M
Engine speed: 1500 rpm
Starting: Electric
Consumption: 4.4 Lt/h at 75% load
Length: 1700 mm
Width: 700 mm
Height: 1050 mm
Weight: 620 Kg
Super-silenced
AVR
If you are looking for a product like this then you can browse the full range of generators or other types of products in our catalogue to find the one that best suits your needs.
Images and technical data are not binding.
- Phase
- Single phase / Three phase
- Maximum power single phase (KW)
- 7.33
- Continuous power single phase (KW)
- 6.67
- Maximum power single phase (KVA)
- 9.1
- Continuous power single phase (KVA)
- 8.3
- Maximum power three phase (KW)
- 22
- Continuous power three phase (KW)
- 20
- Maximum power three phase (KVA)
- 27.5
- Continuous power three phase (KVA)
- 25
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Sockets configuration
- 1 x 400V 32A 5P CEE - 1 x 230V 16A 3P CEE
- Engine
- Kohler KDI 2504 M
- Emissions Regulations
- Stage 3A
- Engine rpm (rpm)
- 1500
- Speed governor
- Mechanical
- Starting system
- Electric
- Engine capacity (cm³)
- 2482
- Number cylinders
- 4
- Cooling
- Water
- Alternator
- Brushless
- Poles
- 4
- Protection degree
- IP44
- Bore x stroke (mm)
- 88 x 102
- Fuel tank capacity (L)
- 55
- Consumption (L/h)
- 4.4
- Running time (h)
- 12.5
- Acoustic pressure
- 68 dB(A) at 7 m
- Length (mm)
- 1700
- Width (mm)
- 700
- Height (mm)
- 1050
- Dry weight (Kg)
- 620
- AVR
- Yes
- Silenced
- Yes
- Super silenced
- Yes
- Product type
- Generator
- ATS Switch device
- No
- Voltage regulator
- AVR
- Engine manufacturer
- Kohler