GENERATOR SILENCED 220KVA SINGLE/THREE PHASE MANUAL PANEL
Phase type: Single-phase / Three-phase
Continuous use power: 200 KVA / 160 KW
Maximum power: 220 KVA / 176 KW
Motor: Perkins 1106A-70TAG4
Revs engine: 1500 rpm
Emissions regulations: Not emitted
Starting: Electric
Fuel: Diesel
Voltage available at terminals: 230/400 V
Frequency: 50 Hz
Voltage regulator: AVR
Socket panel: Terminal block
Tank capacity: 100 l
Autonomy at 75% of the load: 170 h
Consumption at 75% of the load: 34.7 Lt / h
Acoustic pressure: 70 dB (A) @ 7 m
Length: 3300 mm
Width: 1100 mm
Height: 1770 mm
Dry weight: 2140 Kg
- Phase
- Single phase / Three phase
- Maximum power three phase (KW)
- 176
- Continuous power three phase (KW)
- 160
- Maximum power three phase (KVA)
- 220
- Continuous power three phase (KVA)
- 200
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Engine
- PERKINS 1106A-70TAG4, 4 stroke turbo-aftercooler
- Engine rpm (rpm)
- 1500
- Speed governor
- Electronic
- Starting system
- Electric
- Engine capacity (cm³)
- 7010
- Number cylinders
- 6
- Cylinders' position
- In line
- Cooling
- Water
- Alternator
- LINZ PRO 22SD/4 - Sincrono
- Poles
- 4
- Fuel tank capacity (L)
- 170
- Consumption (L/h)
- 24.7 Lt/h al 75% del carico
- Running time (h)
- 9.62 h al 75% del carico
- Acoustic pressure
- 70 dB(A)
- Length (mm)
- 3300
- Width (mm)
- 1100
- Height (mm)
- 1770
- Dry weight (Kg)
- 1730
- Silenced
- Yes
- Super silenced
- Yes
- ATS Switch device
- Optional
- Voltage regulator
- AVR
GENERATOR SILENCED 220KVA SINGLE/THREE PHASE MANUAL PANEL
The generator single-phase / three-phase is equipped with a Perkins 1106A-70TAG4 diesel-powered engine, complete with AVR voltage regulator.
The generator set is equipped with electric start with 12 V battery and low fuel consumption, in fact it consumes only 7.1 liters / hour at 75% of the load, combined with a large 100 l of maximum capacity, it will give you an autonomy of about 14 hours.
The generator is equipped with a soundproof cabin, made of carbon steel 20/10 thick, folded and electro-welded, with protection class IP23 and which can be opened in two sections. This cabin allows the super silenced group to deliver an acoustic pressure of only 65 dB (A) @ 7 meters.
The generator unit guarantees efficient and silent operation thanks to the Perkins 1106A-70TAG4 engine, which allows to deliver a maximum power of 220KVA.
TECHNICAL FEATURES
Type of phase: Single-phase / Three-phase
Continuous use power: 200 KVA / 160 KW
Maximum power: 220 KVA / 176 KW
Motor: Perkins 1106A-70TAG4
Revs engine: 1500 rpm
Emissions regulations: Not emitted
Starting: Electric
Fuel: Diesel
Voltage available at terminals: 230/400 V
Frequency: 50 Hz
Voltage regulator: AVR
Socket panel: Terminal block
Tank capacity: 100 l
Autonomy at 75% of the load: 170 h
Consumption at 75% of the load: 34.7 Lt / h
Acoustic pressure: 70 dB (A) @ 7 m
Length: 3300 mm
Width: 1100 mm
Height: 1770 mm
Dry weight: 2140 Kg
Are you looking for a generator with different technical characteristics? HERE you can find the area dedicated to generating sets of specialized brands.
Non-binding images and technical data.
- Phase
- Single phase / Three phase
- Maximum power three phase (KW)
- 176
- Continuous power three phase (KW)
- 160
- Maximum power three phase (KVA)
- 220
- Continuous power three phase (KVA)
- 200
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Engine
- PERKINS 1106A-70TAG4, 4 stroke turbo-aftercooler
- Engine rpm (rpm)
- 1500
- Speed governor
- Electronic
- Starting system
- Electric
- Engine capacity (cm³)
- 7010
- Number cylinders
- 6
- Cylinders' position
- In line
- Cooling
- Water
- Alternator
- LINZ PRO 22SD/4 - Sincrono
- Poles
- 4
- Fuel tank capacity (L)
- 170
- Consumption (L/h)
- 24.7 Lt/h al 75% del carico
- Running time (h)
- 9.62 h al 75% del carico
- Acoustic pressure
- 70 dB(A)
- Length (mm)
- 3300
- Width (mm)
- 1100
- Height (mm)
- 1770
- Dry weight (Kg)
- 1730
- Silenced
- Yes
- Super silenced
- Yes
- ATS Switch device
- Optional
- Voltage regulator
- AVR