- New
CGM 9000SPE GENERATOR 9KVA SINGLE PHASE STAGEV SILENT AVR
AVAILABLE WHILE STOCKS LAST
Phase type: Single phase
Continuous power: 8.2 KVA / 6.6 KW
Maximum power: 9 KVA / 7.2 KW
Fuel: Petrol
Voltage: 230 V
Frequency: 50 Hz
Engine: 16 HP
Engine rpm: 3000 rpm
Emissions standard: StageV
Starting: Electric
Voltage regulator: AVR
Consumption: 2.1 Lt / h at 75% load
Tank capacity: 25 Lt
Autonomy: 11.9 h at 75% load
Acoustic pressure: 70 dBA @ 7m
Socket panel: 1 x schuko 230V | 1 x CEE 32A 3P 230V socket | 1 x 12VDC socket
Length: 725 mm
Width: 600 mm
Height: 620 mm
Weight: 87 Kg
- Phase
- Single phase
- Maximum power single phase (KW)
- 7.2
- Continuous power single phase (KW)
- 6.6
- Maximum power single phase (KVA)
- 9
- Continuous power single phase (KVA)
- 8.2
- Fuel
- Gasoline
- Frequency (Hz)
- 50
- Voltage (V)
- 230
- Sockets configuration
- 1 x schuko 230V | 1 x CEE 32A 3P 230V socket | 1 x 12VDC socket
- Engine
- 16 HP
- Emissions Regulations
- Stage 5
- Engine rpm (rpm)
- 3000
- Starting system
- Electric
- Engine capacity (cm³)
- 420
- Number cylinders
- 1
- Alternator
- Autoeccitato, con spazzole
- Fuel tank capacity (L)
- 25
- Consumption (L/h)
- 2.1 at 75% of the load
- Running time (h)
- 119 at 75% load
- Acoustic pressure
- 70 dB(A) at 7 m
- Length (mm)
- 725
- Width (mm)
- 600
- Height (mm)
- 620
- Dry weight (Kg)
- 87
- Silenced
- Yes
- Super silenced
- No
- Product type
- Generator
- ATS Switch device
- No
- Voltage regulator
- AVR
CGM 9000SPE GENERATOR 9KVA SINGLE PHASE STAGEV SILENT AVR
CGM 9000SPE single-phase generator with STAGEV petrol engine at 3000 rpm, capable of delivering a maximum power of 9 KVA, with transport trolley supplied as standard, complete with AVR voltage regulator.
The generator is characterized by lower consumption and a longer life expectancy than the petrol-powered range. The generator consists of a self-excited alternator with brushes and with AVR voltage regulator. The CGM 9000SPE generator has a low fuel consumption, in fact it consumes only 2.1 liters / hour at 75% of the load for an autonomy of more than 12 hours of operation.
STAGEV EMISSIONS REGULATION
The generating set is equipped with a "mobile" STAGEV motorization, as required by the European Regulation 2016/1628. These new engines make it possible to exponentially reduce the emissions of particulate matter and nitrogen oxides delivered by the generator into the environment, and ensure a reduction in the environmental impact of 200% compared to standard engines.
AVR VOLTAGE REGULATOR
Its operation is very simple when resistive loads are powered, more complex is the situation in the case of mainly inductive loads: the delayed phase current contrasts the inductor magnetic field, causing a voltage drop at the output terminals of the alternator; to compensate for the phenomenon, the AVR intervenes automatically by increasing the excitation current, until the output returns to the nominal value. If the load is instead capacitive, the current acts as a magnetizer for the inductor causing an increase in the output voltage, and the AVR intervenes by reducing the excitation current
TECHNICAL CHARACTERISTICS CGM 9000SPE:
Phase type: Single phase
Continuous power: 8.2 KVA / 6.6 KW
Maximum power: 9 KVA / 7.2 KW
Fuel: Petrol
Voltage: 230 V
Frequency: 50 Hz
Engine: 16 HP
Engine rpm: 3000 rpm
Emissions standard: StageV
Starting: Electric
Voltage regulator: AVR
Consumption: 2.1 Lt / h at 75% load
Tank capacity: 25 Lt
Autonomy: 11.9 h at 75% load
Acoustic pressure: 70 dBA @ 7m
Socket panel: 1 x schuko 230V | 1 x CEE 32A 3P 230V socket | 1 x 12VDC socket
Length: 725 mm
Width: 600 mm
Height: 620 mm
Weight: 87 Kg
Are you looking for a product with technical characteristics different? HERE you can find the area dedicated to CGM generators or other specialized brands.
The images and technical data are not binding, the color of the group may vary based on availability.
- Phase
- Single phase
- Maximum power single phase (KW)
- 7.2
- Continuous power single phase (KW)
- 6.6
- Maximum power single phase (KVA)
- 9
- Continuous power single phase (KVA)
- 8.2
- Fuel
- Gasoline
- Frequency (Hz)
- 50
- Voltage (V)
- 230
- Sockets configuration
- 1 x schuko 230V | 1 x CEE 32A 3P 230V socket | 1 x 12VDC socket
- Engine
- 16 HP
- Emissions Regulations
- Stage 5
- Engine rpm (rpm)
- 3000
- Starting system
- Electric
- Engine capacity (cm³)
- 420
- Number cylinders
- 1
- Alternator
- Autoeccitato, con spazzole
- Fuel tank capacity (L)
- 25
- Consumption (L/h)
- 2.1 at 75% of the load
- Running time (h)
- 119 at 75% load
- Acoustic pressure
- 70 dB(A) at 7 m
- Length (mm)
- 725
- Width (mm)
- 600
- Height (mm)
- 620
- Dry weight (Kg)
- 87
- Silenced
- Yes
- Super silenced
- No
- Product type
- Generator
- ATS Switch device
- No
- Voltage regulator
- AVR