CUMMINS C22D5Q GENERATOR 22KVA SINGLE-PHASE/THREE-PHASE SILENCED
Phase type: Single-phase / Three-phase
Continuous power: 20 KVA / 16 KW
Maximum power: 22 KVA / 18 KW
Engine: Cummins X2.5-G2
Fuel system: Diesel
Engine speed: 1500 rpm
Regulation of revolutions: Mechanical
Alternator: Stamford S0L2-G1
Emissions standard: Stage ZERO
Starter: Electric / Automatic
Voltage regulator: Compound
Voltage: 230/400 V
Frequency: 50 Hz
Socket panel: Terminal block
Tank capacity: 55 l
Consumption per 75 % load: 4.23 l/h
Autonomy at 75% load: 13 h
Length: 1960 mm
Width: 820 mm
Height: 1285 mm
Weight dry: 715 kg
- Phase
- Single phase / Three phase
- Maximum power three phase (KW)
- 18
- Continuous power three phase (KW)
- 16
- Maximum power three phase (KVA)
- Continuous power three phase (KVA)
- 17.4
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Sockets configuration
- Morsettiera
- Emissions Regulations
- Stationary Use
- Engine rpm (rpm)
- 1500
- Speed governor
- Mechanical
- Number cylinders
- 4
- Cylinders' position
- In line
- Cooling
- Air
- Alternator
- Synchronous, brushless
- Poles
- 4
- Fuel tank capacity (L)
- 55
- Running time (h)
- 13 at 75% of the load
- Acoustic pressure
- 96 dB(A)
- Silenced
- Yes
- Super silenced
- Yes
- Brushes
- No
- Product type
- Generator
- ATS Switch device
- Optional
- Type of alternator
- Constant Speed
- Voltage regulator
- Compound
- Engine manufacturer
- Cummins
- Precision of voltage regulation
- ± 2,5%
CUMMINS C22D5Q GENERATOR 22KVA SINGLE-PHASE/THREE-PHASE SILENCED
The CUMMINS C22D5Q generator is equipped with a Cummins X2.5-G2 engine powered by diesel and is capable of delivering a maximum power of 22KVA, complete with compound voltage regulator.
The CUMMINS C22D5Q is equipped with electric, manual or automatic starting with a 12 V battery, and is equipped with a PowerStart 600 control unit which allows you to view all the parameters electrics of the engine and generator, of the functions, status of the generator set, manage the group entirely and display, if any, the errors or alarms of the system.
The CUMMINS C22D5Q generator is compact and easy to use, equipped with a hood with sound-absorbing panels that significantly lower acoustic emissions and make it supersilent.
The Generator is equipped with an electric start and with low fuel consumption, in fact it consumes about 4 litres/hour at 75% of the load for an autonomy of up to 13 hours of operation. The generating set guarantees efficient and silent operation thanks to the Cummins X2.5-G2 engine, which allows for the delivery of a maximum power of 22KVA.
In addition, it is equipped with automatic starting via the ATS panel, which allows it to start independently in the event of a blackout.
ATS AUTOMATIC STARTER PANEL ARRANGEMENT
The CUMMINS C22D5Q generator is designed for connection to ATS automatic starter panel. Thanks to which you will no longer have to worry about blackouts, since, in the event of a power failure from the mains, this panel is able to turn on the group and will allow you to continue your business without losing your work data.
CUMMINS C22D5Q TECHNICAL SPECIFICATIONS
Phase type: Single-phase / Three-phase
Continuous power: 20 KVA / 16 KW
Maximum power: 22 KVA / 18 KW
Engine: Cummins X2.5-G2
Fuel system: Diesel
Engine speed: 1500 rpm
Regulation of revolutions: Mechanical
Alternator: Stamford S0L2-G1
Emissions standard: Stage ZERO
Starter: Electric / Automatic
Voltage regulator: Compound
Voltage: 230/400 V
Frequency: 50 Hz
Socket panel: Terminal block
Tank capacity: 55 l
Consumption per 75 % load: 4.23 l/h
Autonomy at 75% load: 13 h
Length: 1960 mm
Width: 820 mm
Height: 1285 mm
Weight dry: 715 kg
Are you looking for a generator with different technical characteristics? HERE you can find the full range of CUMMINS generators and other specialized brands.
Non-binding images and technical data
- Phase
- Single phase / Three phase
- Maximum power three phase (KW)
- 18
- Continuous power three phase (KW)
- 16
- Maximum power three phase (KVA)
- Continuous power three phase (KVA)
- 17.4
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Sockets configuration
- Morsettiera
- Emissions Regulations
- Stationary Use
- Engine rpm (rpm)
- 1500
- Speed governor
- Mechanical
- Number cylinders
- 4
- Cylinders' position
- In line
- Cooling
- Air
- Alternator
- Synchronous, brushless
- Poles
- 4
- Fuel tank capacity (L)
- 55
- Running time (h)
- 13 at 75% of the load
- Acoustic pressure
- 96 dB(A)
- Silenced
- Yes
- Super silenced
- Yes
- Brushes
- No
- Product type
- Generator
- ATS Switch device
- Optional
- Type of alternator
- Constant Speed
- Voltage regulator
- Compound
- Engine manufacturer
- Cummins
- Precision of voltage regulation
- ± 2,5%