- New
TECNOGEN PK10TC GENERATOR 10KVA SINGLE-PHASE/THREE-PHASE OPEN
Phase type: Single-phase / Three-phase
Continuous power: 9 KVA / 7.2 KW
Maximum power: 10 KVA / 8 KW
Motor: PERKINS 403D-11G
Power supply: Diesel
Engine speed: 1500 rpm
Regulation of revolutions: Mechanical
Alternator: Mecc Alte ECP3-1L/4
Emissions standard: Stage III A
Starter: Electric / Automatic
Voltage regulator: AVR
Voltage: 230/400 V
Frequency: 50 Hz
Socket panel: Terminal block
Capacity; tank: 50 l
Consumption at 75% of the load: 1.8 l/h
Autonomy at 75% of the load: 27.7 h
Length: 1200 mm
Width: 700 mm
Height: 1030 mm
Dry weight: 335 kg
- Phase
- Single phase / Three phase
- Maximum power three phase (KW)
- 8
- Continuous power three phase (KW)
- 7.2
- Maximum power three phase (KVA)
- 10
- Continuous power three phase (KVA)
- 9
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Sockets configuration
- Terminal box
- Engine
- PERKINS 403D-11G
- Emissions Regulations
- Stage 3A
- Engine rpm (rpm)
- 1500
- Speed governor
- Mechanical
- Starting system
- Electric Automatic/Manual
- Number cylinders
- 3
- Alternator
- Mecc Alte ECP3-1L/4
- Poles
- 4
- Fuel tank capacity (L)
- 50
- Consumption (L/h)
- 1.8 at 75% load
- Running time (h)
- 27.7 at 75% load
- Length (mm)
- 1200
- Width (mm)
- 700
- Height (mm)
- 1030
- Dry weight (Kg)
- 335
- Silenced
- No
- Super silenced
- No
- Brushes
- No
- Product type
- Generator
- Control unit
- DSE6110
- ATS Switch device
- Optional
- Voltage regulator
- AVR
- Engine manufacturer
- Perkins
- Precision of voltage regulation
- 1%
TECNOGEN PK10TC GENERATOR 10KVA SINGLE-PHASE/THREE-PHASE OPEN
The TECNOGEN PK10TC generator equipped with a PERKINS 403D-11G engine powered by Diesel and is capable of delivering a maximum power of 10KVA, complete with AVR voltage regulator.
The TECNOGEN PK10TC Equipped with DSE6110 Control Module that monitors speed, frequency, voltage, current, oil pressure, coolant temperature and fuel level, the modules display warnings, shutdown and fuel status. motor. All information is clear and easy to read on the backlit LCD screen. The module offers a variety of inputs, outputs and motor protections, so the system can easily adapt to a wide range of applications.
The Generator is set to run. equipped with electric start and with low fuel consumption, in fact it consumes around 1.8 litres/hour at 75% of the load for an autonomy of up to 27 hours of operation. The generating set guarantees efficient and silent operation thanks to the PERKINS 403D-11G engine, which allows the delivery of a maximum power of 10KVA.
In addition equipped with automatic starting via the ATS panel, which allows autonomous ignition in the event of a blackout.
ATS AUTOMATIC STARTER PANEL ARRANGEMENT
The TECNOGEN PK10TC Generator is prepared for connection with automatic starter panel ATS. Thanks to which you will no longer have to; worry about black-outs, since, in the event of a power failure from the mains, this panel is switched on. able to turn on the group and it will allow you; to continue your business; without losing your work data.
TECHNICAL CHARACTERISTICS OF TECNOGEN PK10TC
Phase type: Single-phase / Three-phase
Continuous power: 9 KVA / 7.2 KW
Maximum power: 10 KVA / 8 KW
Motor: PERKINS 403D-11G
Power supply: Diesel
Engine speed: 1500 rpm
Regulation of revolutions: Mechanical
Alternator: Mecc Alte ECP3-1L/4
Emissions standard: Stage III A
Starter: Electric / Automatic
Voltage regulator: AVR
Voltage: 230/400 V
Frequency: 50 Hz
Socket panel: Terminal block
Capacity; tank: 50 l
Consumption at 75% of the load: 1.8 l/h
Autonomy at 75% of the load: 27.7 h
Length: 1200 mm
Width: 700 mm
Height: 1030 mm
Dry weight: 335 kg
Are you looking for a generator with different technical characteristics? HERE you can find the entire range of TECNOGEN generators and other specialized brands.
The images and technical data are not binding and may be subject to revisions by the manufacturer.
- Phase
- Single phase / Three phase
- Maximum power three phase (KW)
- 8
- Continuous power three phase (KW)
- 7.2
- Maximum power three phase (KVA)
- 10
- Continuous power three phase (KVA)
- 9
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Sockets configuration
- Terminal box
- Engine
- PERKINS 403D-11G
- Emissions Regulations
- Stage 3A
- Engine rpm (rpm)
- 1500
- Speed governor
- Mechanical
- Starting system
- Electric Automatic/Manual
- Number cylinders
- 3
- Alternator
- Mecc Alte ECP3-1L/4
- Poles
- 4
- Fuel tank capacity (L)
- 50
- Consumption (L/h)
- 1.8 at 75% load
- Running time (h)
- 27.7 at 75% load
- Length (mm)
- 1200
- Width (mm)
- 700
- Height (mm)
- 1030
- Dry weight (Kg)
- 335
- Silenced
- No
- Super silenced
- No
- Brushes
- No
- Product type
- Generator
- Control unit
- DSE6110
- ATS Switch device
- Optional
- Voltage regulator
- AVR
- Engine manufacturer
- Perkins
- Precision of voltage regulation
- 1%