TECNOGEN MI12TC GENERATOR 11,5KVA SINGLE-PHASE/THREE-PHASE OPEN
Phase type: Single-phase / Three-phase
Continuous power: 10.5 KVA / 8 KW
Maximum power: 11.5 KVA / 9 KW
Engine: MITSUBISHI S3L261SD
Power supply: Diesel
br />Engine speed: 1500 rpm
Regulation of revolutions: Mechanical
Alternator: Mecc Alte ECO3-1LN/4
Emissions standard: Not Emissions
Starter: Electric / Automatic
Voltage regulator: AVR
Voltage: 230/400 V
Frequency: 50 Hz
Socket panel: Terminal block
Capacity: tank: 50 l
Consumption at 75% of the load: 2 l/h
Autonomy at 75% of the load: 25 h
Length: 1400 mm
Width: 750 mm
Height: 1000 mm
Dry weight: 375 kg
- Phase
- Single phase / Three phase
- Maximum power three phase (KW)
- 9
- Continuous power three phase (KW)
- 8
- Maximum power three phase (KVA)
- 11.5
- Continuous power three phase (KVA)
- 10.5
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Sockets configuration
- Terminal box
- Engine
- MITSUBISHI S3L261SD
- Emissions Regulations
- Not Emitted
- Engine rpm (rpm)
- 1500
- Speed governor
- Mechanical
- Starting system
- Electric Automatic/Manual
- Number cylinders
- 3
- Alternator
- Mecc Alte ECO3-1LN/4
- Poles
- 4
- Fuel tank capacity (L)
- 50
- Consumption (L/h)
- 2 at 75% load
- Running time (h)
- 25 at 75% load
- Length (mm)
- 1400
- Width (mm)
- 750
- Height (mm)
- 1000
- Dry weight (Kg)
- 375
- Silenced
- No
- Super silenced
- No
- Brushes
- No
- Product type
- Generator
- Control unit
- DSE6110
- ATS Switch device
- Optional
- Voltage regulator
- AVR
- Engine manufacturer
- Mitsubishi
- Precision of voltage regulation
- 1%
TECNOGEN MI12TC GENERATOR 11,5KVA SINGLE-PHASE/THREE-PHASE OPEN
The TECNOGEN MI12TC generator equipped with a MITSUBISHI S3L261SD diesel-powered engine and is capable of delivering a maximum power of 10 KVA, complete with AVR voltage regulator.
The TECNOGEN MI12TC Equipped with DSE6110 Control Module that monitors speed, frequency, voltage, current, oil pressure, coolant temperature and fuel level, the modules display warnings, shutdown and fuel status. motor. All information is clear and easy to read on the backlit LCD screen. The module offers a variety of inputs, outputs and motor protections, so the system can easily adapt to a wide range of applications.
Thanks to the AVR voltage regulator included in the supply of the group, the TECNOGEN MI12TC manages to supply "clean" current and voltage with an accuracy of less than one percent, this guarantees the user the ability to safely connect any type of electrical and electronic device.
The Generator is set to run. equipped with electric start and with low fuel consumption, in fact it consumes around 2 litres/hour at 75% of the load for an autonomy of up to 25 hours of operation. The generating set guarantees efficient and silent operation thanks to the MITSUBISHI S3L261SD engine, which allows to deliver a maximum power of 10KVA.
In addition equipped with automatic starting via the ATS panel, which allows autonomous ignition in the event of a blackout.
ATS AUTOMATIC STARTER PANEL ARRANGEMENT
The TECNOGEN MI12TC Generator prepared for connection with automatic starter panel ATS. Thanks to which you will no longer have to; worry about black-outs, since, in the event of a power failure from the mains, this panel is switched on. able to turn on the group and it will allow you; to continue your business; without losing your work data.
TECHNICAL CHARACTERISTICS OF TECNOGEN MI12TC
Phase type: Single-phase / Three-phase
Continuous power: 10.5 KVA / 8 KW
Maximum power: 11.5 KVA / 9 KW
Engine: MITSUBISHI S3L261SD
Power supply: Diesel
br />Engine speed: 1500 rpm
Regulation of revolutions: Mechanical
Alternator: Mecc Alte ECO3-1LN/4
Emissions standard: Not Emissions
Starter: Electric / Automatic
Voltage regulator: AVR
Voltage: 230/400 V
Frequency: 50 Hz
Socket panel: Terminal block
Capacity: tank: 50 l
Consumption at 75% of the load: 2 l/h
Autonomy at 75% of the load: 25 h
Length: 1400 mm
Width: 750 mm
Height: 1000 mm
Dry weight: 375 kg
Are you looking for a generator with different technical characteristics? HERE you can find the entire range of TECNOGEN generators and other specialized brands.
The images and technical data are not binding and may be subject to revisions by the manufacturer.
- Phase
- Single phase / Three phase
- Maximum power three phase (KW)
- 9
- Continuous power three phase (KW)
- 8
- Maximum power three phase (KVA)
- 11.5
- Continuous power three phase (KVA)
- 10.5
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Sockets configuration
- Terminal box
- Engine
- MITSUBISHI S3L261SD
- Emissions Regulations
- Not Emitted
- Engine rpm (rpm)
- 1500
- Speed governor
- Mechanical
- Starting system
- Electric Automatic/Manual
- Number cylinders
- 3
- Alternator
- Mecc Alte ECO3-1LN/4
- Poles
- 4
- Fuel tank capacity (L)
- 50
- Consumption (L/h)
- 2 at 75% load
- Running time (h)
- 25 at 75% load
- Length (mm)
- 1400
- Width (mm)
- 750
- Height (mm)
- 1000
- Dry weight (Kg)
- 375
- Silenced
- No
- Super silenced
- No
- Brushes
- No
- Product type
- Generator
- Control unit
- DSE6110
- ATS Switch device
- Optional
- Voltage regulator
- AVR
- Engine manufacturer
- Mitsubishi
- Precision of voltage regulation
- 1%