CGM 60P-C50 WITH AUTOMATIC CONTROL PANEL
Phase type: Single-phase / Three-phase
Maximum three-phase power: 52.8 KW / 66 KVA
Three-phase continuous power: 48 KW / 60 KVA
Maximum single-phase power: 17.6 KW / 22 KVA
Single-phase continuous use power: 16 KW / 20 KVA
Fuel: Diesel
Voltage: 230 V / 400 V
Frequency: 50 Hz
Motor: PERKINS 1103A-33TG2
Engine speed: 1500 rpm
Starting: Electric
Consumption: 10.8 Lt/h at 75% load
Length: 2000 mm
Width: 850 mm
Height: 1275 mm
Weight: 960 Kg
Super-silenced
AVR
- Phase
- Single phase / Three phase
- Maximum power single phase (KW)
- 17.6
- Continuous power single phase (KW)
- 16
- Maximum power single phase (KVA)
- 22
- Continuous power single phase (KVA)
- 20
- Maximum power three phase (KW)
- 52.8
- Continuous power three phase (KW)
- 48
- Maximum power three phase (KVA)
- 66
- Continuous power three phase (KVA)
- 60
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Sockets configuration
- Terminal box
- Engine
- Perkins 1103A-33TG2
- Emissions Regulations
- Stationary Use
- Engine rpm (rpm)
- 1500
- Speed governor
- Mechanical
- Starting system
- Electric
- Engine capacity (cm³)
- 3300
- Number cylinders
- 3
- Cooling
- Water
- Alternator
- Brushless
- Poles
- 4
- Protection degree
- IP44
- Bore x stroke (mm)
- 105 x 127
- Fuel tank capacity (L)
- 100
- Consumption (L/h)
- 10.8
- Running time (h)
- 9.2
- Acoustic pressure
- 69 dB(A) at 7 m
- Length (mm)
- 2000
- Width (mm)
- 850
- Height (mm)
- 1275
- Dry weight (Kg)
- 960
- AVR
- Yes
- Silenced
- Yes
- Super silenced
- Yes
- Product type
- Generator
- ATS Switch device
- Optional
- Voltage regulator
- AVR
- Engine manufacturer
- Perkins
CGM 60P-C50 Single/three-phase 60KVA generator super-silenced with automatic control panel
The CGM 60P-C50 is a single/three phase 60KVA generator with a 1500 rpm Perkins diesel engine, compact and easy to use, mounted on a fixed base. This generator is equipped with a soundproofed cabin made of structural steel plate, weatherproofed and lined with high noise reduction material, making the CGM 60P-C50 supersilenced.
The CGM 60P-C50 generator consists of a Stamford, Mecc Alte or Marelli Motori, self-excited, brushless alternator with AVR voltage regulator. The CGM 60P-C50 generator is equipped with an electric starter with a low fuel consumption battery, consuming only 10,8 litres per hour at 75% load. In addition, it has a panel with an automatic control unit and terminal block for automatic start-up.
This generator is perfect for use outdoors, such as on construction sites.
The CGM 60P-C50 generator is part of the Industrial range and is characterised by its versatility for installation in urban environments such as shops or shopping centres, for the telecommunications environment, for military applications and much more.
Technical characteristics of the CGM 60P-C50 generator:
Phase type: Single-phase / Three-phase
Maximum three-phase power: 52.8 KW / 66 KVA
Three-phase continuous power: 48 KW / 60 KVA
Maximum single-phase power: 17.6 KW / 22 KVA
Single-phase continuous use power: 16 KW / 20 KVA
Fuel: Diesel
Voltage: 230 V / 400 V
Frequency: 50 Hz
Motor: PERKINS 1103A-33TG2
Engine speed: 1500 rpm
Starting: Electric
Consumption: 10.8 Lt/h at 75% load
Length: 2000 mm
Width: 850 mm
Height: 1275 mm
Weight: 960 Kg
Super-silenced
AVR
If you are looking for a product like the CGM 60P-C50 then you can browse the full range of CGM generators or other types of products in our catalogue to find the one that best suits your needs.
Images and technical data are not binding.
CGM AUTOMATIC TRANSFER SWITCH ATS 90A
- Phase
- Single phase / Three phase
- Maximum power single phase (KW)
- 17.6
- Continuous power single phase (KW)
- 16
- Maximum power single phase (KVA)
- 22
- Continuous power single phase (KVA)
- 20
- Maximum power three phase (KW)
- 52.8
- Continuous power three phase (KW)
- 48
- Maximum power three phase (KVA)
- 66
- Continuous power three phase (KVA)
- 60
- Fuel
- Diesel
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Sockets configuration
- Terminal box
- Engine
- Perkins 1103A-33TG2
- Emissions Regulations
- Stationary Use
- Engine rpm (rpm)
- 1500
- Speed governor
- Mechanical
- Starting system
- Electric
- Engine capacity (cm³)
- 3300
- Number cylinders
- 3
- Cooling
- Water
- Alternator
- Brushless
- Poles
- 4
- Protection degree
- IP44
- Bore x stroke (mm)
- 105 x 127
- Fuel tank capacity (L)
- 100
- Consumption (L/h)
- 10.8
- Running time (h)
- 9.2
- Acoustic pressure
- 69 dB(A) at 7 m
- Length (mm)
- 2000
- Width (mm)
- 850
- Height (mm)
- 1275
- Dry weight (Kg)
- 960
- AVR
- Yes
- Silenced
- Yes
- Super silenced
- Yes
- Product type
- Generator
- ATS Switch device
- Optional
- Voltage regulator
- AVR
- Engine manufacturer
- Perkins