- New
GENERATOR 9KVA SINGLE PHASE / THREE PHASE STAGEV AVR WITH ATS
Phase type: Single-phase / Three-phase
Continuous use Single-phase: 2.7 KVA / 2.2 KW
Maximum power Single-phase: 3 KVA / 2.4 KW
Continuous use Three-phase: 8.2 KVA / 6.6 KW
Maximum three-phase power: 9 KVA / 7.2 KW
Fuel: Petrol
Voltage: 400 / 230 V
Frequency: 50 Hz
Motor: 16 HP
Revolutions engine: 3000 rpm
Emissions standard: StageV
Starter: Electric
Voltage regulator: AVR
Consumption: 2.1 Lt/h at 75% load
Capacity tank: 25 Lt
Autonomy: 11.9 h at 75% of the load
Acoustic pressure: 70 dBA @ 7m
Socket panel: 1 x schuko 230V | 1 x CEE 16A 5P 400V socket | 1 x 12VDC socket
Length: 725 mm
Width: 600 mm
Height: 620 mm
Weight: 87 Kg
- Phase
- Single phase / Three phase
- Maximum power single phase (KW)
- 2.4
- Maximum power single phase (KVA)
- 3
- Maximum power three phase (KW)
- 7.2
- Maximum power three phase (KVA)
- 9
- Fuel
- Gasoline
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Sockets configuration
- 1 x 400V - 1 x 230V
- Engine
- 16 HP
- Emissions Regulations
- Stage 5
- Engine rpm (rpm)
- 3000
- Starting system
- Manual / Electric
- Engine capacity (cm³)
- 460
- Number cylinders
- 1
- Alternator
- Copper
- Fuel tank capacity (L)
- 25
- Consumption (L/h)
- 2.1
- Running time (h)
- 11.9
- Acoustic pressure
- 70 dB(A) at 7 m
- Length (mm)
- 725
- Width (mm)
- 600
- Height (mm)
- 620
- Dry weight (Kg)
- 87
- Silenced
- No
- Super silenced
- No
- Product type
- Generator
- ATS Switch device
- Yes
- Voltage regulator
- AVR
GENERATOR 9KVA SINGLE PHASE / THREE PHASE STAGEV AVR WITH ATS
Generator Single-phase / three-phase with STAGEV petrol-powered engine at 3000 rpm, capable of delivering a maximum power of 9 KVA, with transport trolley as standard equipment, complete with AVR voltage regulator.
The generator is characterized by lower consumption and a longer life expectancy than the petrol-powered range. The generator consists of a self-excited alternator with brushes and voltage regulator AVR. The generator has low fuel consumption, in fact it consumes only 2.1 litres/hour at 75% of the load for an autonomy of more than 12 hours of operation.
STAGEV EMISSION REGULATIONS
The generator set is equipped with a "mobile" STAGEV engine, as required by European Regulation 2016/1628. These new engines make it possible to exponentially reduce the particulate and nitrogen oxide emissions released by the generator into the environment, and guarantee a 200% reduction in environmental impact compared to standard engines.
AVR VOLTAGE REGULATOR
Its operation is very simple when resistive loads are powered, the situation is more complex in the case of predominantly inductive loads: the delayed phase-shifted current contrasts the inductor magnetic field, causing a drop in voltage at the output terminals of the alternator; to compensate the phenomenon, the AVR intervenes automatically by increasing the excitation current, until the output returns to the nominal value. If the load is instead capacitive, the current acts as a magnet for the inductor causing an increase in the output voltage, and the AVR intervenes by reducing the excitation current.
ATS AUTOMATIC STARTER PANEL ARRANGEMENT
The generator set includes an ATS automatic transfer switch. Thanks to which you will no longer have to worry about blackouts because if the electricity goes off, this panel is able to automatically start the generator and will allow you to continue your business without losing your work data.
TECHNICAL FEATURES:
Phase type: Single-phase / Three-phase
Continuous use Single-phase: 2.7 KVA / 2.2 KW
Maximum power Single-phase: 3 KVA / 2.4 KW
Continuous use Three-phase: 8.2 KVA / 6.6 KW
Maximum three-phase power: 9 KVA / 7.2 KW
Fuel: Petrol
Voltage: 400 / 230 V
Frequency: 50 Hz
Motor: 16 HP
Revolutions engine: 3000 rpm
Emissions standard: StageV
Starter: Electric
Voltage regulator: AVR
Consumption: 2.1 Lt/h at 75% load
Capacity tank: 25 Lt
Autonomy: 11.9 h at 75% of the load
Acoustic pressure: 70 dBA @ 7m
Socket panel: 1 x schuko 230V | 1 x CEE 16A 5P 400V socket | 1 x 12VDC socket
Length: 725 mm
Width: 600 mm
Height: 620 mm
Weight: 87 Kg
You are looking for a product with technical characteristics different? HERE you can find the area dedicated to specialized brands.
The images and technical data are not binding, the color of the group may vary based on availability.
- Phase
- Single phase / Three phase
- Maximum power single phase (KW)
- 2.4
- Maximum power single phase (KVA)
- 3
- Maximum power three phase (KW)
- 7.2
- Maximum power three phase (KVA)
- 9
- Fuel
- Gasoline
- Frequency (Hz)
- 50
- Voltage (V)
- 230 / 400
- Sockets configuration
- 1 x 400V - 1 x 230V
- Engine
- 16 HP
- Emissions Regulations
- Stage 5
- Engine rpm (rpm)
- 3000
- Starting system
- Manual / Electric
- Engine capacity (cm³)
- 460
- Number cylinders
- 1
- Alternator
- Copper
- Fuel tank capacity (L)
- 25
- Consumption (L/h)
- 2.1
- Running time (h)
- 11.9
- Acoustic pressure
- 70 dB(A) at 7 m
- Length (mm)
- 725
- Width (mm)
- 600
- Height (mm)
- 620
- Dry weight (Kg)
- 87
- Silenced
- No
- Super silenced
- No
- Product type
- Generator
- ATS Switch device
- Yes
- Voltage regulator
- AVR