BM2 TITAN 235T HOT AIR GENERATOR (OIL-GAS)
Phase Type: Three-phase
Fuel: Diesel - GAS
Frequency (Hz): 50
Voltage (V): 400
Nominal Thermal Power: 235.72 KW - 202715 Kcal/H - 810861 BTU/H
Power Output: 227. 47 KW - 195620 Kcal/H - 782480 BTU/H
Thermal Efficiency (%): 96.5
Air Flow Rate (M³/H): 20000
Static Pressure Available: 500 Pa - 50 mm H₂O
Thermal Heat Gain At 20°C (°C): 47
Effective Working Range (M): 70
Gasoil Consumption (Kg/H): 18. 65
Methane Consumption (m³/H): 22.035
Methane Feeding Pressure (mbar): 20
LPG Consumption (m³/H - Kg/H): 8.637 - 16. 92
LPG Feeding Pressure (mbar): 37
Electrical Power (W): 4970
Length (mm): 2630
Width (mm): 1042
Height (mm): 1840
Dry Weight (Kg): 535
- Phase
- Three phase
- Fuel
- Diesel - GAS
- Frequency (Hz)
- 50
- Voltage (V)
- 400
- Rated heat power
- 235.72 KW - 202715 Kcal/h - 810861 BTU/h
- Output heat power
- 227.47 KW - 195620 Kcal/h - 782480 BTU/h
- Heat efficiency (%)
- 96.5
- Air flow (m³/h)
- 20000
- Available static press
- 500 Pa - 50 mm H₂O
- Termperature rise at 20°C (°C)
- 47
- Effective heat range (m)
- 70
- Oil consumption (Kg/h)
- 18.65
- Natural Gas consumption (m³/h)
- 22.035
- Inlet pressure Natural Gas (mbar)
- 20
- LPG consumption (m³/h - Kg/h)
- 8.637 - 16.92
- Inlet pressure LPG (mbar)
- 37
- Power consumption (W)
- 4970
- Ø flue (mm)
- 200
- Ø outlet hose - L.max 1 way (mm - m)
- 700 - 50
- Ø outlet hose - L.max 2 ways (mm - m)
- 600 - 30
- Ø outlet hose - L.max 4 ways (mm - m)
- 400 - 25
- Ø outlet snorkel - L.max (mm - m)
- 150 - 6
- Ø inlet hose - L.max (mm - m)
- 750 - 10
- Length (mm)
- 2630
- Width (mm)
- 1042
- Height (mm)
- 1840
- Dry weight (Kg)
- 535
BM2 TITAN 235T HOT AIR GENERATOR (OIL-GAS)
BM2 TITAN 235T is an indirect combustion hot air generator, of large size for more voluminous environments, it can indifferently mount an external oil, LPG or methane burner.
BM2 TITAN 235T is equipped with a centrifugal fan that, in addition to being very quiet, guarantees high prevalence (500 Pa), a feature that is particularly advisable for installations where long ducting is required. The combustion chamber with 5 smoke passes also guarantees a thermal efficiency of 96%.
BM2 TITAN 235T is supplied with:
- Burner cover drawer allowing protection from shock, dust, water, The new heat exchanger combined with the new higher performance fans allow to obtain a thermal efficiency of 96%
- A better anchorage of the supporting structure of the machine thanks to strong fixing brackets that allow its movement on any surface
- Supporting structure with removable panels for internal washing, even when the machine is hanging
- Panels with cross-shaped reinforcing bends to guarantee greater rigidity and strength
- Use of metric screws and inserts only for fastening, no self-tapping screws
- Smoke exhaust protection in combustion chamber made of plastic material with retention chains
Protection fan (IP 55):
- very quiet (noise ≤ 67 db at 2 meters);
- high prevalence and performance that provides a high flow rate and static pressure (500 Pa) for the homogeneous and long-distance diffusion of hot air through ducts or conduits;
- fan anchored to the supporting structure by means of sturdy side members and fixing brackets;
- adjustable damper of restoration;
Rear electric control panel (IP 65):
- positioned in the rear part avoids the contact with dust, water, snow etc;
- provided with a strong metal cover that allows also the shelter of tools and documents;
Front electric service panel (IP 65):
- positioned in the front part of the machine inside the burner cover drawer: to avoid that it is in contact with dust, water, snow for an easier maintenance; for an easier control and intervention of the operator
Each of the main components of the BM2 TITAN 235T is equipped with quick electrical connections:
- speed of installation/disassembly and technical intervention
- elimination of installation/disassembly errors
TECHNICAL FEATURES BM2 TITAN 235T
Phase Type: Three-phase
Fuel: Diesel - GAS
Frequency (Hz): 50
Voltage (V): 400
Nominal Thermal Power: 235.72 KW - 202715 Kcal/H - 810861 BTU/H
Power Output: 227. 47 KW - 195620 Kcal/H - 782480 BTU/H
Thermal Efficiency (%): 96.5
Flow Rate (M³/H): 20000
Static Pressure Available: 500 Pa - 50 mm H₂O
Thermal Heat Gain At 20°C (°C): 47
Effective Working Range (M): 70
Gasoline Consumption (Kg/H): 18. 65
Methane Consumption (m³/H): 22.035
Methane Feeding Pressure (mbar): 20
LPG Consumption (m³/H - Kg/H): 8.637 - 16. 92
LPG Feeding Pressure (mbar): 37
Electrical Power (W): 4970
Length (mm): 2630
Width (mm): 1042
Height (mm): 1840
Dry Weight (Kg): 535
Are you looking for a hot air generator with different technical characteristics? Here you can find the full range of BM2 heaters or other specialized brands.
Images and technical data are not binding and may be subject to revisions by the manufacturer.
BM2 HEAVY DUTY THERMOSTAT WITH CABLE AND PLUG
BM2 ELECTRONIC THERMOSTAT IP55 WITH DISPLAY WITHOUT POWER CORD AND PLUG
BM2 ANTI-WATER FILTER
BM2 TWO-PIPE EXTERNAL FUEL TANK CONNECTION KIT
BM2 QUICK CONNECTION KIT
BM2 ONE-WAY ADAPTER DIAMETER 700 mm FOR TITAN 235
BM2 TWO-WAYS ADAPTER DIAMETER 600 mm FOR TITAN 235
BM2 FOUR-WAYS ADAPTER DIAMETER 400 mm FOR TITAN 235
BM2 AIR INLET ADAPTER DIAMETER 745 mm FOR TITAN 235
BM2 REINFORCED FLEXIBLE AIR INLET DUCT DIAMETER 750 mm FOR TITAN 235
BM2 SWIVELLING WHEELS KIT DIAMETER 200 mm FOR TITAN 235
BM2 ECOFLAM DIESEL BURNER FOR TITAN 235 OIL
BM2 RIELLO DIESEL BURNER FOR TITAN 235 OIL
BM2 LPG RIELLO BURNER + GAS TRAIN FOR TITAN 235 LPG
BM2 NATURAL GAS RIELLO BURNER + GAS TRAIN FOR TITAN 235 NATURAL GAS
BM2 SNORKEL PASS PLATE DIAMETER 150 mm FOR TITAN 235
BM2 FLEXIBLE DUCT DIAMETER 150 mm FOR TITAN 235
BM2 AIR OUTLET FIRE SHUTTER KIT (REI 120) FOR TITAN 235
BM2 AIR INLET FIRE SHUTTER KIT (REI 120) DIAMETER 745 mm FOR TITAN 235
BM2 PRE-HEATED FUEL FILTER FOR TITAN
BM2 SINGLE-PIPE EXTERNAL FUEL TANK CONNECTION KIT WITH DE-AERATOR FOR TITAN
BM2 GAS FILTER FOR TITAN 185-235
BM2 GAS FILTER REGULATOR FOR TITAN 185-235
BM2 MEDIUM PRESSURE GAS HOSE + GAS VALVE + CONNECTIONS FOR TITAN 185-235
BM2 STAINLESS STEEL EXHAUST PIPE DIAMETER 200 mm FOR TITAN 145-185-235
BM2 STAINLESS STEEL CHIMNEY POT DIAMETER 200 mm FOR TITAN 145-185-235
BM2 CHIMNEY SUPPORT KIT FOR TITAN 145-185-235
BM2 CHIMNEY HOLDER KIT FOR TITAN 235
- Phase
- Three phase
- Fuel
- Diesel - GAS
- Frequency (Hz)
- 50
- Voltage (V)
- 400
- Rated heat power
- 235.72 KW - 202715 Kcal/h - 810861 BTU/h
- Output heat power
- 227.47 KW - 195620 Kcal/h - 782480 BTU/h
- Heat efficiency (%)
- 96.5
- Air flow (m³/h)
- 20000
- Available static press
- 500 Pa - 50 mm H₂O
- Termperature rise at 20°C (°C)
- 47
- Effective heat range (m)
- 70
- Oil consumption (Kg/h)
- 18.65
- Natural Gas consumption (m³/h)
- 22.035
- Inlet pressure Natural Gas (mbar)
- 20
- LPG consumption (m³/h - Kg/h)
- 8.637 - 16.92
- Inlet pressure LPG (mbar)
- 37
- Power consumption (W)
- 4970
- Ø flue (mm)
- 200
- Ø outlet hose - L.max 1 way (mm - m)
- 700 - 50
- Ø outlet hose - L.max 2 ways (mm - m)
- 600 - 30
- Ø outlet hose - L.max 4 ways (mm - m)
- 400 - 25
- Ø outlet snorkel - L.max (mm - m)
- 150 - 6
- Ø inlet hose - L.max (mm - m)
- 750 - 10
- Length (mm)
- 2630
- Width (mm)
- 1042
- Height (mm)
- 1840
- Dry weight (Kg)
- 535