GENERATOR WITH MANUAL PANEL 1000lt TANK

  • New
GENERATOR WITH MANUAL PANEL 1000lt TANK
search
  • GENERATOR WITH MANUAL PANEL 1000lt TANK
  • MANUAL CONTROL PANEL
CGM
Generatore 1000lt Manuale
New product

Phase type: Single-phase / Three-phase
Maximum three-phase power: 26.4 KW / 33 KVA
Three-phase continuous power: 24 KW / 30 KVA
Single-phase maximum power: 8.8 KW / 11 KVA
Single-phase continuous use power: 8 KW / 10 KVA
Fuel: Diesel
Voltage: 230 V / 400 V
Frequency: 50 Hz
Motor: PERKINS 1103A-33G
Motor speed: 1500 rpm
Starting: Electric
Consumption: 5.6 Lt/h at 75% load
Length: 2000 mm
Width: 850 mm
Height: 1280 mm
Weight: 930 Kg
Supersilenced
AVR
Emission category: EU STAGE 0
Autonomy: 178 h

Technical features
Phase
Single phase / Three phase
Maximum power single phase (KW)
8.8
Continuous power single phase (KW)
8
Maximum power single phase (KVA)
11
Continuous power single phase (KVA)
10
Maximum power three phase (KW)
26.4
Continuous power three phase (KW)
24
Maximum power three phase (KVA)
33
Continuous power three phase (KVA)
30
Fuel
Diesel
Frequency (Hz)
50
Voltage (V)
230 / 400
Sockets configuration
Engine
Perkins 1103A-33G
Emissions Regulations
Stationary Use
Engine rpm (rpm)
1500
Speed governor
Mechanical
Starting system
Electric
Engine capacity (cm³)
3300
Number cylinders
3
Cooling
Water
Alternator
Brushless
Poles
4
Protection degree
IP44
Bore x stroke (mm)
105 x 127
Fuel tank capacity (L)
1000
Consumption (L/h)
5.6
Running time (h)
178
Acoustic pressure
69 dB(A) at 7 m
Length (mm)
2000
Width (mm)
850
Height (mm)
1280
Dry weight (Kg)
930
AVR
Yes
Silenced
Yes
Super silenced
Yes
Product type
Generator
ATS Switch device
No
Voltage regulator
AVR
Engine manufacturer
Perkins
Details

Single/three-phase 30KVA super-silenced genset with manual panel 1000lt tank

30KVA single/three-phase genset with 1500 rpm diesel-powered Perkins engine, compact and easy to use, mounted on a fixed base. This generator is equipped with a soundproofed cabin made of structural steel plate, weatherproofed and with an internal lining of high noise-abatement material that makes it supersilenced.

The genset consists of a Stamford, Mecc Alte or Marelli Motori alternator, self-excited, brushless and with AVR voltage regulator. The genset has an electric start with a low fuel consumption battery, consuming only 178 litres/hour at 75% load. For greater convenience of use the tank.

This genset is perfect for use outdoors, such as on construction sites.

The genset is part of the Industrial range and is characterised by versatility for installation in urban environments such as shops or shopping centres, for the telecommunications environment, for military applications and much more.

Technical characteristics of the genset

Phase type: Single-phase / Three-phase
Maximum three-phase power: 26.4 KW / 33 KVA
Three-phase continuous power: 24 KW / 30 KVA
Single-phase maximum power: 8.8 KW / 11 KVA
Single-phase continuous use power: 8 KW / 10 KVA
Fuel: Diesel
Voltage: 230 V / 400 V
Frequency: 50 Hz
Motor: PERKINS 1103A-33G
Motor speed: 1500 rpm
Starting: Electric
Consumption: 5.6 Lt/h at 75% load
Length: 2000 mm
Width: 850 mm
Height: 1280 mm
Weight: 930 Kg
Supersilenced
AVR
Emission category: EU STAGE 0
Autonomy: 178 h

If you are looking for a product such as a Generator Set then you can browse the entire range of generators or others in our catalogue to find the one that best suits your needs.

Images and technical data are not binding.

Related Accessories
List price
24.863,60 € tax incl.
20.380,00 € tax excl.
Discounted Price
14.670,50 € tax incl.
12.025,00 € tax excl.
Quantity

loader
295,00 € shipped to Italy

Calculate Shipping Cost
Add to wishlist
Download PDF
Ask a question
Product: GENERATOR WITH MANUAL PANEL 1000lt TANK
Offer on letterhead
Product: GENERATOR WITH MANUAL PANEL 1000lt TANK
Technical features
Phase
Single phase / Three phase
Maximum power single phase (KW)
8.8
Continuous power single phase (KW)
8
Maximum power single phase (KVA)
11
Continuous power single phase (KVA)
10
Maximum power three phase (KW)
26.4
Continuous power three phase (KW)
24
Maximum power three phase (KVA)
33
Continuous power three phase (KVA)
30
Fuel
Diesel
Frequency (Hz)
50
Voltage (V)
230 / 400
Sockets configuration
Engine
Perkins 1103A-33G
Emissions Regulations
Stationary Use
Engine rpm (rpm)
1500
Speed governor
Mechanical
Starting system
Electric
Engine capacity (cm³)
3300
Number cylinders
3
Cooling
Water
Alternator
Brushless
Poles
4
Protection degree
IP44
Bore x stroke (mm)
105 x 127
Fuel tank capacity (L)
1000
Consumption (L/h)
5.6
Running time (h)
178
Acoustic pressure
69 dB(A) at 7 m
Length (mm)
2000
Width (mm)
850
Height (mm)
1280
Dry weight (Kg)
930
AVR
Yes
Silenced
Yes
Super silenced
Yes
Product type
Generator
ATS Switch device
No
Voltage regulator
AVR
Engine manufacturer
Perkins
Details